RLY3-OSSD300: 1099969 - Sick RLY3 Safety Relay
Technical Specifications of Sick RLY3 Safety Relay RLY3-OSSD300 1099969:
Spec | Value |
---|---|
Safety Integrity Level | SIL 3 (IEC 61508) |
Connection Types | Front connector with spring terminals |
Outputs | 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) |
Configuration Method | Hard wired |
Sick RLY3 Safety Relay RLY3-OSSD300, 1099969 Technical Specifications:
Specification | Value |
---|---|
Compatible sensor types | Safety sensors with OSSDs |
Safety integrity level | SIL 3 (IEC 61508) |
Category | Category 4 (ISO 13849-1) |
Performance level | PL e (ISO 13849-1) |
TM (mission time) | 20 years (ISO 13849-1) |
Sensor monitoring | Sequence monitoring |
Restart interlock | ✔ |
Reset | Automatic, Manual |
External device monitoring (EDM) | ✔ |
Connection type | Front connector with spring terminals |
Inputs | 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM) |
Outputs | 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) |
Display elements | LEDs |
Configuration method | Hard wired |
Supply voltage VS | 24 V DC (16.8 V ... 30 V) |
Residual ripple | ≤ 2.4 V |
Power consumption | ≤ 2.5 W (DC) |
Input voltage HIGH | 24 V DC (11 V ... 30 V) |
Input voltage LOW | 0 V DC (–3 V ... 5 V) |
Input current | 4 mA ... 6 mA |
Test pulse width | ≤ 1 ms |
Test pulse rate | ≤ 10 Hz |
Response time | 12 ms |
Type of output | N/O contacts, positively guided |
Contact material | Silver alloy, gold flashed |
Switching voltage | 10 V AC ... 230 V AC, 10 V DC ... 230 V DC |
Switching current | 10 mA ... 6 A |
Total current | 12 A |
Overvoltage category | III (EN 60664-1) |
Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
Output voltage HIGH | ≥ Vs – 3 V |
Output voltage LOW | ≤ 3 V |
Input current (NPN) | ≤ 15 mA |
Output current (PNP) | ≤ 120 mA |
Output voltage | ≥ Vs – 3 V |
Test pulse interval | 40 ms |
Dimensions (W x H x D) | 18 mm x 124.6 mm x 85.5 mm |
Enclosure rating | IP20 (IEC 60529) |
Ambient operating temperature | –25 °C ... +55 °C |
Storage temperature | –25 °C ... +70 °C |
Air humidity | ≤ 95 %, Non-condensing |
Interference emission | According to IEC 61000-6-4 |
Interference resistance | According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1 |
Weight | 150 g |
IndMALL Automation Dealing offers Sick RLY3 Safety Relay RLY3-OSSD300 part no: 1099969 at unbeatable prices. The Main Technical Parameters of RLY3-OSSD300, 1099969 features Safety sensors with OSSDs and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features Sequence monitoring, Automatic, Manual reset. The relay has a Front connector with spring terminals, 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM). Outputs include 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) and LEDs for display elements and is configured through a Hard wired method. It supports 24 V DC (16.8 V ... 30 V) supply voltage, ≤ 2.4 V residual ripple, and ≤ 2.5 W (DC) power consumption.
The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (–3 V ... 5 V), with an input current of 4 mA ... 6 mA . The test pulse width is ≤ 1 ms, and the test pulse rate is ≤ 10 Hz, with a response time of 12 ms. The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. Output voltage HIGH is ≥ Vs – 3 V, and output voltage LOW is ≤ 3 V. The input current (NPN) is ≤ 15 mA, and the output current (PNP) is ≤ 120 mA, with an output voltage of ≥ Vs – 3 V and a test pulse interval of 40 ms. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of –25 °C ... +55 °C and storage temperatures of –25 °C ... +70 °C, with air humidity of ≤ 95 %, Non-condensing. Take the First Step with a Quote for your requirement of Sick RLY3 Safety Relay. Choose us for unparalleled pricing and support over other Dealers & Distributors.