RLY3-TIME100: 1100688 - Sick Safety Control Relay

Technical Specifications of Sick Safety Control Relay RLY3-TIME100 1100688:

SpecValue
Safety Integrity LevelSIL 3 (IEC 61508)
Connection TypesFront connector with spring terminals
Outputs2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Configuration MethodHard wired, DIP switch

Sick Safety Control Relay RLY3-TIME100, 1100688 Technical Specifications:

SpecificationValue
Compatible sensor typesSafety sensors with OSSDs, Safety sensors with potential-free outputs
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (ISO 13849-1)
Performance levelPL e (ISO 13849-1)
TM (mission time)20 years (ISO 13849-1)
Sensor monitoringDiscrepancy monitoring, Sequence monitoring, Cross-circuit detection
Restart interlock
ResetAutomatic, Manual
External device monitoring (EDM)
Connection typeFront connector with spring terminals
Inputs2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM)
Outputs2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Display elementsLEDs
Configuration methodHard wired, DIP switch
Supply voltage VS24 V DC (16.8 V ... 30 V)
Residual ripple≤ 2.4 V
Power consumption≤ 2.5 W (DC)
Input voltage HIGH24 V DC (11 V ... 30 V)
Input voltage LOW0 V DC (–3 V ... 5 V)
Input current4 mA ... 6 mA
Test pulse width≤ 1 ms
Test pulse rate≤ 10 Hz
Response time12 ms
Type of outputN/O contacts, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage10 V AC ... 230 V AC, 10 V DC ... 230 V DC
Switching current10 mA ... 6 A
Total current12 A
Overvoltage categoryIII (EN 60664-1)
Rated impulse withstand voltage Uimp6 kV (EN 60664-1)
Output voltage HIGH≥ Vs – 3 V
Output voltage LOW≤ 3 V
Input current (NPN)≤ 15 mA
Output current (PNP)≤ 120 mA
Output voltage≥ Vs – 3 V
Test pulse interval40 ms
Dimensions (W x H x D)18 mm x 124.6 mm x 85.5 mm
Enclosure ratingIP20 (IEC 60529)
Ambient operating temperature–25 °C ... +55 °C
Storage temperature–25 °C ... +70 °C
Air humidity≤ 95 %, Non-condensing
Interference emissionAccording to IEC 61000-6-4
Interference resistanceAccording to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1
Weight160 g
Ask for the Pricing of Sick Safety Control Relay RLY3-TIME100 part no: 1100688 at unbeatable prices. Detailed Specifications of RLY3-TIME100, 1100688 features Safety sensors with OSSDs, Safety sensors with potential-free outputs and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features Discrepancy monitoring, Sequence monitoring, Cross-circuit detection, Automatic, Manual reset. The relay has a Front connector with spring terminals, 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM). Outputs include 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) and LEDs for display elements and is configured through a Hard wired, DIP switch method. It supports 24 V DC (16.8 V ... 30 V) supply voltage, ≤ 2.4 V residual ripple, and ≤ 2.5 W (DC) power consumption. The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (–3 V ... 5 V), with an input current of 4 mA ... 6 mA . The test pulse width is ≤ 1 ms, and the test pulse rate is ≤ 10 Hz, with a response time of 12 ms. The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. Output voltage HIGH is ≥ Vs – 3 V, and output voltage LOW is ≤ 3 V. The input current (NPN) is ≤ 15 mA, and the output current (PNP) is ≤ 120 mA, with an output voltage of ≥ Vs – 3 V and a test pulse interval of 40 ms. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of –25 °C ... +55 °C and storage temperatures of –25 °C ... +70 °C, with air humidity of ≤ 95 %, Non-condensing. Now's the Time to Secure a Quote for your requirement of Sick Safety Control Relay. We're committed to offering more favorable pricing and more responsive support than other Traders.