Technical Specifications of Sick Compact 2D LiDAR Sensor TIM100-3010200 1077524:

SpecValue
Light SourceInfrared (850 nm)
Connection Type1 x 5-pin M12 male device connector (rotatable)
Dimensions (L x W x H)60 mm x 60 mm x 75.8 mm
Digital outputs2 (Push-pull)

Sick Compact 2D LiDAR Sensor TIM100-3010200, 1077524 Technical Specifications:

SpecificationValue
ApplicationIndoor
Light sourceInfrared (850 nm)
Laser class1 (IEC 60825-1:2014, EN 60825-1:2014)
Aperture angleHorizontal, 200°
Scanning frequency14.5 Hz
Angular resolution
Heating-
Working range0.05 m ... 3 m
Scanning rangeAt 10% remission factor, 1.2 m ... 1.5 m, depending on the angle
Connection type1 x 5-pin M12 male device connector (rotatable)
Supply voltage9 V DC ... 28 V DC
Power consumptionTyp. 2.2 W
Housing-
Housing colorLight blue (RAL 5012)
Enclosure ratingIP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection classIII (IEC 61140:2016-1)
Weight90 g, without connecting cables
Dimensions (L x W x H)60 mm x 60 mm x 75.8 mm
MTBF50 years
MTTFD> 100 years
Detectable object shapeAlmost any
Systematic error± 50 mm
Statistical error20 mm
Ethernet-
Serial-
Digital outputs2 (Push-pull)
Optical indicators2 LEDs (ON, switching status)
Ambient operating temperature–10 °C ... +50 °C
Storage temperature–30 °C ... +70 °C
Please speak to our Technical Engineer for Sick Compact 2D LiDAR Sensor TIM100-3010200 part no: 1077524 at attractive prices. Technical Specs Summary of TIM100-3010200, 1077524 includes Indoor applications, using an Infrared (850 nm) light source and classified as Laser Class 1 (IEC 60825-1:2014, EN 60825-1:2014). It offers a Horizontal, 200° aperture angle with a scanning frequency of 14.5 Hz and operates within a working range of 0.05 m ... 3 m, with a scanning range At 10% remission factor, 1.2 m ... 1.5 m, depending on the angle. It connects 1 x 5-pin M12 male device connector (rotatable) and requires a 9 V DC ... 28 V DC supply voltage, consuming Typ. 2.2 W for heating. colored Light blue (RAL 5012), with an IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013) enclosure rating and protection class III (IEC 61140:2016-1). The dimensions of 60 mm x 60 mm x 75.8 mm. The MTBF is 50 years, and MTTFD is > 100 years. The sensor has a systematic error of ± 50 mm and a statistical error of 20 mm, 2 (Push-pull) output. It operates between –10 °C ... +50 °C and can be stored between –30 °C ... +70 °C. Match Your Needs with a Quote for your requirement of Sick Compact 2D LiDAR Sensor. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.