Tecnhical specifications of Sick 24 Voltage Safe Signal Processing SRB-E-602EM 103041589:

SpecValue
MountingSnaps onto standard DIN rail to EN 60715
Terminationrigid or flexible, Screw connection, plug-in
Width22.5 mm
Height98 mm
Depth115 mm
SpecificationValue
Housing materialGlass-fibre reinforced thermoplastic, ventilated
Gross weight269 g
PFH value, Stop 02.00 x 10⁻⁸ /h
MountingSnaps onto standard DIN rail to EN 60715
Terminationrigid or flexible, Screw connection, plug-in
Cable section, minimum0.25 mm²
Cable section, maximum2.5 mm²
Tightening torque of Clips0.5 Nm
Width22.5 mm
Height98 mm
Depth115 mm
Degree of protection of the enclosureIP40
Degree of protection of the mounting spaceIP54
Degree of protection of clips or terminalsIP20
Ambient temperature-25 ... +60 °C
Storage and transport temperature-40 ... +85 °C
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock10 g / 11 ms
Rated impulse withstand voltage Uimp4 kV
Frequency range50 Hz, 60 Hz
Operating voltage24 VAC -15 % / +10 %24 VDC -15 % / +20 %
Ripple voltage10 %
Rated operating voltage24 VDC
Electrical power consumption4.9 VA
Contact resistance, maximum0.1 Ω
Drop-out delay, maximum35 ms
Pull-in delay at automatic start, maximum, typically20 ms
Material of the contacts, electricalAg-Ni, self-cleaning, positive drive
Switching capacity, minimum10 mA
Switching capacity, maximum2 A
Conduction resistance, maximum40 Ω
Get A Quote for Sick 24 Voltage Safe Signal Processing SRB-E-602EM part no: 103041589 at the best price. Here are the brief Technical Specifications of SRB-E-602EM, 103041589 are Glass-fibre reinforced thermoplastic, ventilated design, ensuring robust protection and longevity. The sensor is easy to install, Snaps onto standard DIN rail to EN 60715 and the Termination is handled via rigid or flexible, Screw connection, plug-in methods, allowing for both rigid or flexible wiring options. With dimensions of 22.5 mm in Width, 98 mm in Height, and 115 mm in Depth, this compact sensor fits seamlessly into various setups. It operates within a Frequency range of 50 Hz, 60 Hz with an Operating voltage of 24 VAC -15 % / +10 %24 VDC -15 % / +20 %. The Rated operating voltage is 24 VDC and the Electrical power consumption is minimal at just 4.9 VA. It's Time to get a Quote for your requirement of Sick 24 Voltage Safe Signal Processing. We guarantee unmatched pricing and unparalleled support compared to other Distributors.