ECOR-1-BSC3/2X21: 2907518 - Phoenix 1 or 2 Changeover Contacts Relay Socket
Technical Specifications of Phoenix 1 or 2 Changeover Contacts Relay Socket ECOR-1-BSC3/2X21 2907518:
Spec | Value |
---|---|
Product Type | Relay socket |
Connection Method | Screw connection |
Screw Thread | M3 |
Mounting Type | DIN rail mounting |
Phoenix 1 or 2 Changeover Contacts Relay Socket ECOR-1-BSC3/2X21, 2907518 Technical Specifications:
Specification | Value |
---|---|
Product type | Relay socket |
Product family | ESSENTIAL edition |
Nominal voltage UN | 250 V AC/DC |
Nominal current IN | 12 A |
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 2x 0.2 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible | 2x 0.2 mm² ... 2.5 mm² (without ferrule) |
Width | 15.7 mm |
Height | 79.2 mm |
Depth Retaining bracket | 69 mm (ECOR-RH-1L) |
Color | traffic grey B (RAL 7043) |
Ambient temperature (operation) | -25 °C ... 70 °C |
Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Mounting type | DIN rail mounting |
Mounting position | any |
Application | - |
Protective circuit | - |
Nominal input voltage UN | - |
Conductor cross section AWG | - |
Tightening torque | - |
Status display | - |
Depth | - |
Flammability rating according to UL 94 | - |
Enclosure Low | - |
Low Voltage Directive | - |
Electromagnetic compatibility | - |
Diameter | - |
Compatible components | - |
Input voltage range in reference to UN | - |
Typical input current at UN | - |
Typical response time | - |
Typical release time | - |
Typical release voltage | - |
Operating voltage display | - |
Maximum switching voltage | - |
Minimum switching voltage | - |
Limiting continuous current | - |
Voltage drop at max. limiting continuous current | - |
Output circuit | - |
Maximum inrush current | - |
Leakage current | - |
Phase angle cos phi min | - |
Max. load value | - |
Insulation | - |
Overvoltage category | - |
Test voltage (Winding/contact) | - |
Test voltage () | - |
Rated insulation voltage | - |
Rated surge voltage | - |
Degree of protection | - |
Standards/regulations | - |
Rated control circuit supply voltage US | - |
Voltage range with reference to US | - |
Rated control supply current IS | - |
Rated actuating voltage UC | - |
Voltage range with reference to UC | - |
Rated actuating current IC | - |
Surge voltage protection | - |
Switching level 1 signal ("H") (TTL signal) | - |
Switching level 0 signal ("L") (TTL signal) | - |
Transmission frequency Test voltage relay winding/relay contact | - |
Switching threshold "0" signal, voltage | - |
Mail Us for your needs in Phoenix 1 or 2 Changeover Contacts Relay Socket ECOR-1-BSC3/2X21 part no: 2907518 with budget-friendly prices. The Main Technical Parameters of ECOR-1-BSC3/2X21, 2907518 inludce Product family ESSENTIAL edition, designed for versatile industrial applications. This sensor features a reliable Screw connection method, accommodating conductor cross sections of 2x 0.2 mm² ... 2.5 mm² (without ferrule), whether rigid or flexible 2x 0.2 mm² ... 2.5 mm² (without ferrule). The sensor has compact dimensions, with a width of 15.7 mm and a height of 79.2 mm, making it suitable for space-constrained installations. The housing is finished in traffic grey B (RAL 7043), ensuring a professional appearance. It operates efficiently within ambient temperatures ranging from -25 °C ... 70 °C, both during operation and storage. The sensor is designed for easy DIN rail mounting, allowing for flexible mounting positions in any orientation. Customize Your Experience with a Quote for your requirement of Phoenix 1 or 2 Changeover Contacts Relay Socket. Experience the difference with our competitive pricing and superior support over other Suppliers.