ATV610D90N4: Schneider Electric 125 HP VFD

Technical Specifications of Schneider Electric 125 HP VFD ATV610D90N4:

SpecValue
Mounting modeCabinet mount
Output Voltage<= power supply voltage
Connector Type1 RJ45 (on the remote graphic terminal) for Modbus serial
Relay Output TypeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles

Schneider Electric 125 HP VFD ATV610D90N4 Technical Specifications:

SpecificationValue
Mounting modeCabinet mount
Height762 mm922 mm with EMC plate
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Range of productEasy Altivar 610
Ambient air temperature for operation-15…45 °C (without derating)45…60 °C (with derating factor)
Communication port protocolModbus serial
Operating positionVertical +/- 10 degree
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output
Product destinationAsynchronous motorsSynchronous motors
IP degree of protectionIP20
number of preset speeds16 preset speeds
Line current177.8 A at 380 V (normal duty)159.9 A at 460 V (normal duty)155.8 A at 380 V (heavy duty)138.1 A at 460 V (heavy duty)
Braking to standstillBy DC injection
Number of Units in Package 2-
Analogue input number3
Output voltage<= power supply voltage
Analogue output typeSoftware-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Sampling duration5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output
Depth323 mm
Acceleration and deceleration rampsLinear adjustable separately from 0.01 to 9000 sS, U or customized
Product specific applicationFan, pump, compressor, conveyor
Continuous output current173 A at 2.5 kHz for normal duty145 A at 2.5 kHz for heavy duty
Apparent power127.4 kVA at 460 V (normal duty)110.0 kVA at 460 V (heavy duty)
Product or component typeVariable speed drive
Width290 mm
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Maximum transient current190 A during 60 s (normal duty)218 A during 60 s (heavy duty)
Physical interface2-wire RS 485 for Modbus serial
EMC filterIntegrated conforming to IEC 61800-3 category C3 with 50 m
Discrete input typeDI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Ambient air temperature for storage-40…70 °C
Noise level78 dB conforming to 86/188/EEC
Relay output number3
Discrete input logicPositive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
Connector type1 RJ45 (on the remote graphic terminal) for Modbus serial
Relay Output TypeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Net Weight53 kg
Motor power hp125 hp for normal duty100 hp for heavy duty
Electrical connectionControl, screw terminal: 0.5...1.5 mm²Line side, screw terminal: 95...120 mm²Motor, screw terminal: 95...120 mm²
Transmission frameRTU for Modbus serial
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Pollution degree2 conforming to IEC 61800-5-1
Analogue output number2
Switching frequency1...8 kHz adjustable
Motor power kW90 kW for normal duty75 kW for heavy duty
Supply frequency50...60 Hz +/-5 %
Output frequency0.1…500 Hz
Protection typeThermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive
Type of coolingForced convection
Get A Quote for Schneider Electric 125 HP VFD ATV610D90N4 at the best price. Here are the brief Technical Specifications of ATV610D90N4 are Cabinet mount, it supports a height range of 762 mm922 mm with EMC plate. This sensor operates using the Modbus serial communication protocol, ensuring seamless integration with the Easy Altivar 610 system. The operating position is Vertical +/- 10 degree. It delivers continuous output <= power supply voltage and is ideal for applications such as Fan, pump, compressor, conveyor. With a continuous output current of 173 A at 2.5 kHz for normal duty145 A at 2.5 kHz for heavy duty, the sensor handles significant loads. It has an apparent power of 127.4 kVA at 460 V (normal duty)110.0 kVA at 460 V (heavy duty). The product features a 2-wire RS 485 for Modbus serial interface and 1 RJ45 (on the remote graphic terminal) for Modbus serial connector. The switching frequency is adjustable from 1...8 kHz adjustable, and it supports a supply frequency of 50...60 Hz +/-5 % with an output frequency range of 0.1…500 Hz. It's Time to get a Quote for your requirement of Schneider Electric 125 HP VFD. We guarantee unmatched pricing and unparalleled support compared to other Distributors.