TM221C40R | Schneider Modicon 40 IO Relay Controller
+91 79955 44066 sales@indmall.in

TM221C40R: Schneider Modicon 40 IO Relay Controller

Technical specifications of Schneider Modicon 40 IO Relay Controller TM221C40R rm)9tb7765x9:

SpecValue
[Us] rated supply voltage100...240 V AC
IP degree of protectionIP20 with protective cover in place
Supply voltage limits85…264 V
Ambient air temperature for operation-10…55 °C (horizontal installation)-10…35 °C (vertical installation)
Protection typeWithout protection at 5 A

Schneider Modicon 40 IO Relay Controller TM221C40R Technical Specifications:

SpecificationValue
Electromagnetic emissionConducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-24 kV on contact conforming to IEC 61000-4-2
Ambient air temperature for storage-25…70 °C
Power supply output current0.52 A 5 V for expansion bus0.24 A 24 V for expansion bus
Discrete output voltage5...125 V DC5...250 V AC
Discrete input voltage5...125 V DC5...250 V AC
IP degree of protectionIP20 with protective cover in place
[Us] rated supply voltage100...240 V AC
StandardsIEC 61131-2UL 508CAN/CSA C22.2 No. 213IACS E10ANSI/ISA 12-12-01
Response time35 µs turn-off, I2...I5 terminal(s) for input10 ms turn-on for output10 ms turn-off for output5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input35 µs turn-on, other terminals terminal(s) for input5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input100 µs turn-off, other terminals terminal(s) for input
Immunity to microbreaks10 ms
Relative humidity10…95 %, without condensation (in operation)10…95 %, without condensation (in storage)
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232480 Mbit/s for USB
Maximum power consumption in W-
Ambient air temperature for operation-10…55 °C (horizontal installation)-10…35 °C (vertical installation)
Discrete input current7 mA for discrete input5 mA for fast input
Supply voltage limits85…264 V
Maximum voltage drop-
Surge withstand2 kV power lines (AC) common mode conforming to IEC 61000-4-52 kV relay output common mode conforming to IEC 61000-4-51 kV I/O common mode conforming to IEC 61000-4-51 kV shielded cable common mode conforming to IEC 61000-4-50.5 kV power lines (DC) differential mode conforming to IEC 61000-4-51 kV power lines (AC) differential mode conforming to IEC 61000-4-51 kV relay output differential mode conforming to IEC 61000-4-50.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Discrete output current2 A
Port Ethernet-
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail3.5 mm at 5…8.4 Hz on panel mounting1 gn at 8.4…150 Hz on symmetrical rail1 gn at 8.4…150 Hz on panel mounting
Communication port protocolUSB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Shock resistance98 m/s² for 11 ms
Protection typeWithout protection at 5 A
IndMALL Automation Dealing offers Schneider Modicon 40 IO Relay Controller TM221C40R at unbeatable prices. The Main Technical Parameters of TM221C40R are ambient air storage temperatures ranging from -25…70 °C, ensuring durability under various conditions. It features 4 fast input (HSC mode) at 100 kHz 32 bits resolution, ideal for precise operations. The package width is 120.0 cm, and it supports a discrete output voltage of 5...125 V DC5...250 V AC, with Relay normally open-type outputs. The discrete input voltage type is DC, and the sensor comes equipped with 16 relay outputs for enhanced performance. The discrete input current is 7 mA for discrete input5 mA for fast input inputs. With a compact depth of 70 mm, this sensor integrates seamlessly into industrial setups, supporting a total of 40 discrete I/O points. It is designed to operate at altitudes up to 0...2000 m, making it suitable for a wide range of applications. Take the First Step with a Quote for your requirement of Schneider Modicon 40 IO Relay Controller. Choose us for unparalleled pricing and support over other Dealers & Distributors.