Technical Specifications of Schneider Thermomagnetic Breaker GZ1 3 Pole GZ1E06:

SpecValue
Mounting SupportRail
Power Dissipation2.5 W (per pole)
Mounting ModeBy screwsBy clips
Connections TerminalsScrew clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end

Schneider Thermomagnetic Breaker GZ1 3 Pole GZ1E06 Technical Specifications:

SpecificationValue
Device applicationMotor
mounting positionAny position
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Ambient air temperature for operation-20…60 °C
Mounting supportRail
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Electrical durability100000 cycles for AC-3
RangeEasy TeSys
Magnetic tripping current22.5 A
Product or component typeCircuit breaker
poles description3P
Width44.5 mm
Control typePush-button
IP degree of protectionIP20 conforming to IEC 60529
ColourGrey (RAL 7011)
Power dissipation2.5 W (per pole)
mounting modeBy screwsBy clips
Operating altitude2000 m
Fire resistance960 °C conforming to IEC 60695-2-1
Thermal protection adjustment range1…1.6 A
Net weight0.26 kg
Motor power kW0.37 kW at 400 V AC 50/60 Hz0.55 kW at 440 V AC 50/60 Hz0.75 kW at 500 V AC 50/60 Hz1.1 kW at 690 V AC 50/60 Hz
Network typeAC
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Device short nameGZ1E
Utilisation categoryAC-3
Maximum operating rate25 cyc/h
Range of productEasy TeSys Power
Ambient air temperature for storage-40…80 °C
Network frequency50/60 Hz conforming to IEC 60947-2
Depth78 mm
Trip unit technologyThermal-magnetic
Height89 mm
Connections - terminalsScrew clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end
Obtain a Quote for Schneider Thermomagnetic Breaker GZ1 3 Pole GZ1E06 at economical prices. Specifications Overview for GZ1E06 reveals Motor applications, suitable for installation in Any position. It has a rated impulse to withstand voltage [Uimp] of 6 kV conforming to IEC 60947-2 standards, ensuring robust protection. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C and can be mounted on a Rail for flexible installation. Its rated operational voltage [Ue] is 690 V AC 50/60 Hz conforming to IEC 60947-2, providing reliable power handling. With the electrical durability of 100000 cycles for AC-3 applications, this sensor ensures long-lasting performance. The magnetic tripping current is set at 22.5 A, and it features a 3P configuration. Take the First Step with a Quote for your requirement of Schneider Thermomagnetic Breaker GZ1 3 Pole. Our commitment to better pricing and exceptional support sets us apart from other Competitors.