LC1G1854LSEA | Schneider 4 Pole 305A High Power Contactor
+91 79955 44066 sales@indmall.in

LC1G1854LSEA: Schneider 4 Pole 305A High Power Contactor

Technical Specifications of Schneider 4 Pole 305A High Power Contactor LC1G1854LSEA:

SpecValue
Power Dissipation Per Pole20 W AC-1 - Ith 305 A6 W AC-3 - Ith 185 A
Range of ProductTeSys Giga
Pole Contact Composition4 NO
Connection TerminalsPower circuit: bar 2 - busbar cross section: 25 x 6 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end

Schneider 4 Pole 305A High Power Contactor LC1G1854LSEA Technical Specifications:

SpecificationValue
Device short nameLC1G
Power dissipation per pole20 W AC-1 - Ith 305 A6 W AC-3 - Ith 185 A
Ambient air temperature for operation-25…60 °C
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz<= 460 V DC
Range of productTeSys Giga
Rated breaking capacity1610 A at 440 V
Auxiliary contact composition1 NO + 1 NC
Maximum operating rate600 cyc/h AC-3600 cyc/h AC-3e300 cyc/h AC-1
Width143 mm
Poles description4P
Utilisation categoryAC-3AC-3eAC-1AC-5aAC-5bAC-6aAC-6bDC-1DC-3DC-5
ColourDark grey
Control circuit voltage limitsOperational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
Motor power hp-
Height255 mm
Mechanical durability8 Mcycles
[Ie] rated operational current185 A (at <60 °C) at <= 440 V AC-3305 A (at <40 °C) at <= 1000 V AC-1
Operating time40...70 ms closing15...50 ms opening
Pole contact composition4 NO
Ambient air temperature for storage-60…80 °C
Product or component typeContactor
[Uc] control circuit voltage200...500 V AC 50/60 Hz200...500 V DC
Tightening torque18 N.m
Depth193 mm
Associated fuse rating200 A aM at <= 440 V for motor160 A aM at <= 690 V for motor315 A gG at <= 690 V
[Icw] rated short-time withstand current1.5 kA - 10 s0.92 kA - 30 s0.74 kA - 1 min0.5 kA - 3 min0.4 kA - 10 min
Motor power kW-
Net weight5.1 kg
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529IP2X front face with shrouds conforming to VDE 0106
hold-in power consumption in W (DC)8.0 W
RangeTeSys
Connections - terminalsPower circuit: bar 2 - busbar cross section: 25 x 6 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end
[Uimp] rated impulse withstand voltage8 kV
Mounting supportPlate
Connection pitch35 mm
[Ui] rated insulation voltage1000 V
IndMALL Automation Dealing offers Schneider 4 Pole 305A High Power Contactor LC1G1854LSEA at unbeatable prices. The Main Technical Parameters of LC1G1854LSEA are device short name LC1G, designed for efficient power management in industrial applications. The sensor has a power dissipation per pole of 20 W AC-1 - Ith 305 A6 W AC-3 - Ith 185 A, ensuring energy-efficient operation. It operates within a broad ambient temperature range of -25…60 °C, making it suitable for various environmental conditions. The rated operational voltage [Ue] is up to <= 1000 V AC 50/60 Hz<= 460 V DC, providing robust power handling. Its rated breaking capacity reaches 1610 A at 440 V, ensuring reliable performance during switching. The auxiliary contact composition includes 1 NO + 1 NC, enhancing flexibility in control applications. With the mechanical durability of 8 Mcycles, the sensor guarantees long-lasting reliability. Operating times include a closing time of 40...70 ms closing15...50 ms opening quick and responsive operation. Take the First Step with a Quote for your requirement of Schneider 4 Pole 305A High Power Contactor. Choose us for unparalleled pricing and support over other Dealers & Distributors.