LC1E3201M7: Schneider 32A Easy TeSys 220V AC 3P Contactor
Technical Specifications of Schneider 32A Easy TeSys 220V AC 3P Contactor LC1E3201M7:
Spec | Value |
---|---|
Product Component Type | Contactor |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
Power Dissipation Per Pole | 2 W AC-35 W AC-1 |
Tightening Torque | Control circuit: 1.2 N.mPower circuit: 2.1 N.m |
Schneider 32A Easy TeSys 220V AC 3P Contactor LC1E3201M7 Technical Specifications:
Specification | Value |
---|---|
Range | Easy TeSys |
Range of product | Easy TeSys Control |
Product or component type | Contactor |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
Motor power kW | 7.5 kW at 220...230 V AC 50/60 Hz15 kW at 380...400 V15 kW at 415 V15 kW at 440 V18.5 kW at 500 V18.5 kW at 660...690 V |
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 50 A (at 55 °C) |
Irms rated making capacity | 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 256 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit138 A 40 °C - 60 s for power circuit60 A 40 °C - 600 s for power circuit |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit |
Power dissipation per pole | 2 W AC-35 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
Control circuit type | AC at 50/60 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz |
Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C)95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C)8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 2…3 W for control circuit |
Operating time | 12...22 ms on closing4...19 ms on opening |
Maximum operating rate | 1800 cyc/h 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end |
Tightening torque | Control circuit: 1.2 N.mPower circuit: 2.1 N.m |
Auxiliary contact composition | 1 NC |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Mounting support | PlateDIN rail |
IP degree of protection | IP2X conforming to IEC 60529 |
Height | 84 mm |
Width | 56 mm |
Depth | 86 mm |
Net weight | 0.45 kg |
Call us for Schneider 32A Easy TeSys 220V AC 3P Contactor LC1E3201M7 at the best rates. Technical Attributes of LC1E3201M7 are Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 220 V AC 50/60 Hz, with 3 NO poles. The conventional free air thermal current is rated at 50 A (at 55 °C), and power dissipation per pole is 2 W AC-35 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Unlock Exclusive Pricing with a Quote for your requirement of Schneider 32A Easy TeSys 220V AC 3P Contactor. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.