POG 9 + FSL: Baumer High-Resolution Pulse Encoder
Technical Specifications of Baumer High-Resolution Pulse Encoder POG 9 + FSL :
Spec | Value |
---|---|
Voltage Supply | 9...30 VDC, 5 VDC ±5 % |
Sensing Method | Optical |
Switching Outputs | 1 output, speed control |
Connection | 2x terminal box |
Baumer High-Resolution Pulse Encoder POG 9 + FSL Technical Specifications:
Specification | Value |
---|---|
Voltage supply | 9...30 VDC, 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 300 … 5000 |
Phase shift | 90 ° ±20° |
Duty cycle | 40…60 % |
Reference signal | Zero pulse, width 90° |
Sensing method | Optical |
Output signals | K1, K2, K0 + inverted, Error output (option EMS) |
Output stages | HTL-P (power linedriver), TTL/RS422 |
Switching accuracy | ± 4 % (Δn = 2 rpm/s);, 20 % (Δn = 1500 rpm/s) |
Switching outputs | 1 output, speed control |
Output switching capacity | ≤6 A / 230 VAC, ≤1 A / 125 VDC, (EAC: <50 VAC / 75 VDC) |
Switching hysteresis | 40 % of switching speed |
Size (flange) | ø115 mm |
Shaft type | ø11 mm solid shaft |
Admitted shaft load | ≤250 N axial, ≤350 N radial |
Flange | EURO flange B10 |
Protection EN 60529 | IP 56 |
Operating torque typ. | 3 Ncm |
Rotor moment of inertia | 220 gcm² |
Material | Housing: aluminium die-cast, Shaft: stainless steel |
Operating temperature | -30...+100 °C, -25...+100 °C (>3072 pulses) |
Resistance | IEC 60068-2-6, Vibration 5 g, 10-2000 Hz, IEC 60068-2-27, Shock 150 g, 1 ms |
Corrosion protection | IEC 60068-2-52 Salt mist, for ambient conditions C4 according to ISO 12944-2 |
Connection | 2x terminal box |
Weight approx. | 1.9 kg |
Get A Quote for Baumer High-Resolution Pulse Encoder POG 9 + FSL part no: at the best price. Here are the brief Technical Specifications of POG 9 + FSL, are voltage supply of 9...30 VDC, 5 VDC ±5 % and pulses per revolution ranging from 300 … 5000. The encoders provide a phase shift of 90 ° ±20° and a duty cycle of 40…60 %, with a Zero pulse, width 90°. Using Optical sensing technology, the encoders offer output signals including K1, K2, K0 + inverted, Error output (option EMS). The available output stages are HTL-P (power linedriver), TTL/RS422, ensuring versatile performance. The encoders come in an ø115 mm flange size and operate at speeds of up to -30...+100 °C, -25...+100 °C (>3072 pulses). Constructed with a durable Housing: aluminium die-cast, Shaft: stainless steel, they offer connections via 2x terminal box. It's Time to get a Quote for your requirement of Baumer High-Resolution Pulse Encoder. We guarantee unmatched pricing and unparalleled support compared to other Distributors.