H3DK-M1A DC12: Omron High Level Voltage Input Timer
Technical Specifications of Omron High Level Voltage Input Timer H3DK-M1A DC12:
Spec | Value |
---|---|
Rated power supply voltage | 12 VDC Ripple 20% max. |
Allowable voltage variable range | 90 to 110% of the power supply voltage |
Voltage Input | High level: 10.8 to 13.2 VDC Low level: 0 to 1.2 VDC |
Reset voltage | 10% max. of rated supply voltage |
Omron High Level Voltage Input Timer H3DK-M1A DC12 Technical Specifications:
Specification | Value |
---|---|
Rated power supply voltage | 12 VDC Ripple 20% max. |
Allowable voltage variable range | 90 to 110% of the power supply voltage |
Input signals | Start |
Operating resetting | - |
Input method | Voltage input |
Star-delta transfer time | - |
Voltage input | High level: 10.8 to 13.2 VDC Low level: 0 to 1.2 VDC |
Power consumption | Approx. 0.6 W (at 12 VDC) |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 8 |
Operation mode | ON delay, Flicker OFF start, Flicker ON start, Signal ON/OFF delay, Signal OFF delay, Interval, One shot output |
Control output (Type) | Time-limit: SPDT |
Control output (Contact output) | Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC/0.5 A max. at 125 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Ambient temperature range | Operating: -20 to 55 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing) |
Ambient humidity range | Operating: 25 to 85% |
Accuracy of operating time | ±1% FS max. (±1% ±10 ms in a range of 1.2 s) |
Setting error | ±10% FS ±0.05 s max. |
Influence of voltage | ±0.5% FS max. (±0.5% ±10 ms in a range of 1.2 s) |
Influence of temperature | ±2% FS max. (±2% ±10 ms in a range of 1.2 s) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 1 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
Noise immunity | ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Degree of protection | IP30 (Terminal Block: IP20) |
Connecting method | Terminal blocks |
Accessories | User label |
Weight | Approx. 120 g |
Ask for the Pricing of Omron High Level Voltage Input Timer, H3DK-M1A DC12 at unbeatable prices. Detailed Specifications of H3DK-M1A DC12 feature Terminal blocks, Operating: -20 to 55 ℃ (with no icing)
Storage: -40 to 70 ℃ (with no icing), ON delay, Flicker OFF start, Flicker ON start, Signal ON/OFF delay, Signal OFF delay, Interval, One shot output, 8. Moreover, it features 10% max. of rated supply voltage, Approx. 0.6 W (at 12 VDC), 12 VDC Ripple 20% max.. Now's the Time to Secure a Quote for your requirement of Omron High Level Voltage Input Timer. We're committed to offering more favorable pricing and more responsive support than other Traders.