Technical Specifications of Omron Voltage Input Range Timer H3DT-L1 AC/DC24-240:
Spec | Value |
---|---|
Rated Power Supply Voltage | 24 to 240 VAC 50/60 Hz 24 to 240 VDC Ripple 20% max. |
Allowable Voltage Variable range | 85% to 110% of rated voltage |
Input Signals | Start |
Input Method | Voltage input |
Omron Voltage Input Range Timer H3DT-L1 AC/DC24-240 Technical Specifications:
Specification | Value |
---|---|
Rated power supply voltage | 24 to 240 VAC 50/60 Hz 24 to 240 VDC Ripple 20% max. |
Allowable voltage variable range | 85% to 110% of rated voltage |
Input signals | Start |
Input method | Voltage input |
Voltage input | High level: 20.4 to 264 VAC/VDC Low level: 0 to 2.4 VAC/VDC |
Power consumption | Approx. 2.0 VA (at 240 VAC) Approx. 0.9 W (at 240 VDC)/Approx. 0.3 W (at 24 VDC) |
Reset voltage | 10% min. of rated voltage. |
Number of time ranges | 8 |
Operation mode | ON delay (Signal ON delay), Flicker OFF Start (Signal Start), Flicker ON Start (Signal Start), Signal ON/OFF delay, Interval (Signal Start), One-shot Output (Signal Start), One-shot Output (Power ON Start) |
Control output (Type) | Time-limit: SPDT |
Control output (Contact output) | Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC/0.5 A max. at 125 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Ambient temperature range | Operating: -20 to 60 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing) |
Ambient humidity range | Operating: 25 to 85% |
Accuracy of operating time | ±1% FS max. (±1% ±10 ms in a range of 1.2 s) |
Setting error | ±10% FS ±0.05 s max. |
Influence of voltage | ±0.5% FS max. (±0.5% ±10 ms in a range of 1.2 s) |
Influence of temperature | ±2% FS max. (±2% ±10 ms in a range of 1.2 s) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between charged metal part and operating section: 2,900 VAC 50/60 Hz for 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 5 kV Between conductor terminal and operating section: 7.4 kV |
Noise immunity | ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Degree of protection | IP30 (Terminal Block: IP20) |
Connecting method | Push-In Plus Terminal Block |
Weight | Approx. 100 g |
Call us for Omron Voltage Input Range Timer, H3DT-L1 AC/DC24-240 at the best rates. Technical Attributes of H3DT-L1 AC/DC24-240 are Approx. 2.0 VA (at 240 VAC)
Approx. 0.9 W (at 240 VDC)/Approx. 0.3 W (at 24 VDC) 24 to 240 VAC 50/60 Hz
24 to 240 VDC Ripple 20% max. 85% to 110% of rated voltage. And It Delivers Start, Voltage input, High level: 20.4 to 264 VAC/VDC
Low level: 0 to 2.4 VAC/VDC.Unlock Exclusive Pricing with a Quote for your requirement of Omron Voltage Input Range Timer. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.