H3FA-A DC5: Omron 5V DC 1s Contact Timer
Technical Specifications of Omron 5V DC 1s Contact Timer H3FA-A DC5:
Spec | Value |
---|---|
Rated Power Supply Voltage | 5 VDC Ripple 3% max. |
Number of Time Ranges | 4 |
Operation Mode | Power ON-delay, Cumulative |
Control Output Type | Time-limit: SPST-NO ,Time-limit: SPST-NC |
Omron 5V DC 1s Contact Timer H3FA-A DC5 Technical Specifications:
Specification | Value |
---|---|
Rated power supply voltage | 5 VDC Ripple 3% max. |
Allowable voltage variable range | 90 to 110% of the power supply voltage |
Power consumption | Approx. 230 mW |
Number of time ranges | 4 |
Operation mode | Power ON-delay, Cumulative |
Control output (Type) | Time-limit: SPST-NO ,Time-limit: SPST-NC |
Control output (Contact output) | Resistive load: 3 A at 250 VAC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Operating resetting | Time-limit operation/power-OFF resetting and external resetting, Integrating operation/power-OFF resetting and external resetting |
Ambient temperature range | Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
Ambient humidity range | Operating: 35 to 85% |
Accuracy of operating time | ±0.5% FS max. (±0.5% ±10 ms in a range of 1 s) |
Setting error | 0 to +30% FS max. (at 20 ℃, rated voltage) |
Reset time | 10 ms max. |
Influence of voltage | ±2% FS max. |
Influence of temperature | ±5% FS max. (±5% ±10 ms in a range of 1 s) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between control output terminals and operating circuit: 1,500 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Vibration resistance | Destruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.25 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Connecting method | PCB terminal |
Weight | Approx. 15 g |
Send Your Inquiry for Omron 5V DC 1s Contact Timer, H3FA-A DC5 with cost-effective solutions. Essential Technical Specs of H3FA-A DC5 cover Approx. 15 g, PCB terminal, 100 MΩ min. (at 500 VDC), ±2% FS max., 10 ms max., Time-limit: SPST-NO ,Time-limit: SPST-NC, Power ON-delay, Cumulative & Approx. 230 mW. It also delivers 90 to 110% of the power supply voltage, 5 VDC Ripple 3% max. & 4. Capture the Best Deal with a Quote for your requirement of Omron 5V DC 1s Contact Timer. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.