Technical Specifications of Omron Low DC 10min Solid-State Timer H3FA-SAU DC5/6:

SpecValue
Rated Power Supply Voltage5/6 VDC Ripple 3% max.
Number of Time Ranges4
Operation ModeOne shot output, Signal OFF delay
Control Output TypeTransistor output

Omron Low DC 10min Solid-State Timer H3FA-SAU DC5/6 Technical Specifications:

SpecificationValue
Rated power supply voltage5/6 VDC Ripple 3% max.
Allowable voltage variable rangefor 5 VDC: 90 to 110% of the power supply voltage/for 6 VDC: 85 to 110% of the power supply voltage
Power consumptionApprox. 80 mW
Number of time ranges4
Operation modeOne shot output, Signal OFF delay
Control output (Type)Transistor output
Control output (Contact output)150 mA max. at 30 VDC, ON residual voltage: 1.0 V max.
Operating resettingInstantaneous operation, time-limit resetting/external resetting
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Ambient humidity rangeOperating: 35 to 85%
Accuracy of operating time±0.5% FS max. (±0.5% ±10 ms in a range of 1 s)
Setting error0 to +30% FS max. (at 20 ℃, rated voltage)
Reset time10 ms max.
Influence of voltage±2% FS max.
Influence of temperature±5% FS max. (±5% ±10 ms in a range of 1 s)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween control output terminals and operating circuit: 1,500 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Vibration resistanceDestruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.25 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output)-
Connecting methodPCB terminal
WeightApprox. 10 g
Give Us a Call for Omron Low DC 10min Solid-State Timer, H3FA-SAU DC5/6 at the lowest pricing. In-depth Technical Analysis of H3FA-SAU DC5/6 includes 5/6 VDC Ripple 3% max., for 5 VDC: 90 to 110% of the power supply voltage/for 6 VDC: 85 to 110% of the power supply voltage, Approx. 80 mW, 4, One shot output, Signal OFF delay, Transistor output, 10 ms max. & ±2% FS max.. It functionality Includes 100 MΩ min. (at 500 VDC), PCB terminal & Approx. 10 g . Elevate Your Project with a Quote for your requirement of Omron Low DC 10min Solid-State Timer. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.