H3FA-SB DC5/6: Omron Low DC 6min Solid-State Timer
Technical Specifications of Omron Low DC 6min Solid-State Timer H3FA-SB DC5/6:
Spec | Value |
---|---|
Rated Power Supply Voltage | 5/6 VDC Ripple 3% max. |
Number of Time Ranges | 4 |
Operation Mode | Power ON-delay, Cumulative |
Control Output Type | Transistor output |
Omron Low DC 6min Solid-State Timer H3FA-SB DC5/6 Technical Specifications:
Specification | Value |
---|---|
Rated power supply voltage | 5/6 VDC Ripple 3% max. |
Allowable voltage variable range | for 5 VDC: 90 to 110% of the power supply voltage/for 6 VDC: 85 to 110% of the power supply voltage |
Power consumption | Approx. 80 mW |
Number of time ranges | 4 |
Operation mode | Power ON-delay, Cumulative |
Control output (Type) | Transistor output |
Control output (Contact output) | 150 mA max. at 30 VDC, ON residual voltage: 1.0 V max. |
Operating resetting | Time-limit operation/power-OFF resetting and external resetting, Integrating operation/power-OFF resetting and external resetting |
Ambient temperature range | Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
Ambient humidity range | Operating: 35 to 85% |
Accuracy of operating time | ±0.5% FS max. |
Setting error | 0 to +30% FS max. (at 20 ℃, rated voltage) |
Reset time | 10 ms max. |
Influence of voltage | ±2% FS max. |
Influence of temperature | ±5% FS max. |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between control output terminals and operating circuit: 1,500 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Vibration resistance | Destruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.25 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | - |
Connecting method | PCB terminal |
Weight | Approx. 10 g |
Send Your Inquiry for Omron Low DC 6min Solid-State Timer, H3FA-SB DC5/6 with cost-effective solutions. Essential Technical Specs of H3FA-SB DC5/6 cover Approx. 10 g
, PCB terminal, 100 MΩ min. (at 500 VDC), ±2% FS max., 10 ms max., Transistor output, Power ON-delay, Cumulative & Approx. 80 mW. It also delivers for 5 VDC: 90 to 110% of the power supply voltage/for 6 VDC: 85 to 110% of the power supply voltage, 5/6 VDC Ripple 3% max. & 4. Capture the Best Deal with a Quote for your requirement of Omron Low DC 6min Solid-State Timer. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.