H3YN-2-B DC125: Omron DC125 Voltage Timer
Technical Specifications of Omron DC125 Voltage Timer H3YN-2-B DC125:
Spec | Value |
---|---|
Rated power supply voltage | 125 VDC If power supply incorporates a single-phase full-wave rectifier. |
Allowable voltage variable range | 85 to 110% of the power supply voltage |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 4 |
Control output (Type) | Time-limit: DPDT |
Omron DC125 Voltage Timer H3YN-2-B DC125 Technical Specifications:
Specification | Value |
---|---|
Rated power supply voltage | 125 VDC If power supply incorporates a single-phase full-wave rectifier. |
Allowable voltage variable range | 85 to 110% of the power supply voltage |
Power consumption | Relay ON: Approx. 1.6 W (at 125 VDC)/Relay OFF: Approx. 0.4 W (at 125 VDC) |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 4 |
Operation mode | ON delay, Interval, Flicker OFF start, Flicker ON start |
Control output (Type) | Time-limit: DPDT |
Control output (Contact output) | Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) |
Ambient temperature range | Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
Ambient humidity range | Operating: 35 to 85% |
Accuracy of operating time | ±1% FS max. (±1% ±10 ms in a range of 1 s) |
Setting error | ±10% FS ±50 ms max. |
Reset time | 0.1 s max. (including halfway reset) |
Influence of voltage | ±2% FS max. |
Influence of temperature | ±2% FS max. |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded) Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 3 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
Noise immunity | ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h, Room temperature) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Degree of protection | IP40 |
Connecting method | 8-pin round socket (Push-In Plus Terminal Block) |
Case color | Black |
Weight | Approx. 50 g |
Talk to Our Engineer for Omron DC125 Voltage Timer, H3YN-2-B DC125 with exclusive offers. Core System Specifications of H3YN-2-B DC125 are Approx. 50 g, ±1% FS max. (±1% ±10 ms in a range of 1 s), Operating: 35 to 85%, Operating: -10 to 55 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing). And It Comes With Time-limit: DPDT, Omron DC125 Voltage Timer H3YN-2-B DC125 Technical Specifications:, https://indmall.in/datasheets/omron/timers/h3y-datasheet.pdf. Don't Miss Out on a Quote for your requirement of Omron DC125 Voltage Timer. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.