H3YN-4 AC24 | Omron 24 VAC 50/60 Hz Timer | IndMALL
+91 79955 44066 sales@indmall.in

H3YN-4 AC24: Omron 24 VAC 50/60 Hz Timer

Technical Specifications of Omron 24 VAC 50/60 Hz Timer H3YN-4 AC24:

SpecValue
Rated power supply voltage24 VAC 50/60 Hz
Allowable voltage variable range85 to 110% of the power supply voltage
Reset voltage10% max. of rated supply voltage
Number of time ranges4
Control output (Type)Time-limit: 4PDT

Omron 24 VAC 50/60 Hz Timer H3YN-4 AC24 Technical Specifications:

SpecificationValue
Rated power supply voltage24 VAC 50/60 Hz
Allowable voltage variable range85 to 110% of the power supply voltage
Power consumptionRelay ON: Approx. 1.8 VA (at 24 VAC 60 Hz)/Relay OFF: Approx. 0.3 VA (at 24 VAC 60 Hz) Relay ON: Approx. 1.4 W (at 24 VAC 60 Hz)/Relay OFF: Approx. 0.2 W (at 24 VAC 60 Hz)
Reset voltage10% max. of rated supply voltage
Number of time ranges4
Operation modeON delay, Interval, Flicker OFF start, Flicker ON start
Control output (Type)Time-limit: 4PDT
Control output (Contact output)Resistive load: 3 A at 250 VAC (cosφ=1) Minimum applicable load: 1 mA at 1 VDC (failure level: P)
Ambient temperature rangeOperating: -10 to 50 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Ambient humidity rangeOperating: 35 to 85%
Accuracy of operating time±1% FS max. (±1% ±10 ms in a range of 1 s)
Setting error±10% FS ±50 ms max.
Reset time0.1 s max. (including halfway reset)
Influence of voltage±2% FS max.
Influence of temperature±2% FS max.
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded) Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 1 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV
Noise immunity±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityMulfunction: 4 kV, Destruction: 8 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output)Electrical: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h, Room temperature) Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Degree of protectionIP40
Connecting method14-pin round socket
Case colorBeige
WeightApprox. 50 g
Talk to Our Engineer for Omron 24 VAC 50/60 Hz Timer, H3YN-4 AC24 with exclusive offers. Core System Specifications of H3YN-4 AC24 are Approx. 50 g, ±1% FS max. (±1% ±10 ms in a range of 1 s), Operating: 35 to 85%, Operating: -10 to 50 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing). And It Comes With Time-limit: 4PDT, Omron 24 VAC 50/60 Hz Timer H3YN-4 AC24 Technical Specifications:, https://indmall.in/datasheets/omron/timers/h3y-datasheet.pdf. Don't Miss Out on a Quote for your requirement of Omron 24 VAC 50/60 Hz Timer. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.