H3YN-41-Z-B DC24: Omron DC24 Z Specialized Timer
Technical Specifications of Omron DC24 Z Specialized Timer H3YN-41-Z-B DC24:
Spec | Value |
---|---|
Rated power supply voltage | 24 VDC If power supply incorporates a single-phase full-wave rectifier. |
Allowable voltage variable range | 85 to 110% of the power supply voltage |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 4 |
Control output (Type) | Time-limit: 4PDT |
Omron DC24 Z Specialized Timer H3YN-41-Z-B DC24 Technical Specifications:
Specification | Value |
---|---|
Rated power supply voltage | 24 VDC If power supply incorporates a single-phase full-wave rectifier. |
Allowable voltage variable range | 85 to 110% of the power supply voltage |
Power consumption | Relay ON: Approx. 1.1 W (at 24 VDC)/Relay OFF: Approx. 0.1 W (at 24 VDC) |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 4 |
Operation mode | ON delay, Interval, Flicker OFF start, Flicker ON start |
Control output (Type) | Time-limit: 4PDT |
Control output (Contact output) | Resistive load: 3 A at 250 VAC (cosφ=1) Minimum applicable load: 1 mA at 1 VDC (failure level: P) |
Ambient temperature range | Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
Ambient humidity range | Operating: 35 to 85% |
Accuracy of operating time | ±1% FS max. (±1% ±10 ms in a range of 1 s) |
Setting error | ±10% FS ±50 ms max. |
Reset time | 0.1 s max. (including halfway reset) |
Influence of voltage | ±2% FS max. |
Influence of temperature | ±2% FS max. |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded) Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 1 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
Noise immunity | ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h, Room temperature) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Degree of protection | IP40 |
Connecting method | 14-pin round socket (Push-In Plus Terminal Block) |
Case color | Black |
Weight | Approx. 50 g |
Give Us a Call for Omron DC24 Z Specialized Timer, H3YN-41-Z-B DC24 at the lowest pricing. In-depth Technical Analysis of H3YN-41-Z-B DC24 includes ±1% FS max. (±1% ±10 ms in a range of 1 s), Operating: 35 to 85%, Operating: -10 to 55 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing), Time-limit: 4PDT. It functionality Includes Resistive load: 3 A at 250 VAC (cosφ=1)
Minimum applicable load: 1 mA at 1 VDC (failure level: P), Omron DC24 Z Specialized Timer H3YN-41-Z-B DC24 Technical Specifications:, https://indmall.in/datasheets/omron/timers/h3y-datasheet.pdf. Elevate Your Project with a Quote for your requirement of Omron DC24 Z Specialized Timer. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.