H5CN-YAN AC100-240 | Omron AC DOWN Short Timer | IndMALL
+91 79955 44066 sales@indmall.in

H5CN-YAN AC100-240: Omron AC DOWN Short Timer

Technical Specifications of Omron AC DOWN Short Timer H5CN-YAN AC100-240:

SpecValue
Rated Supply Voltage100 to 240 VAC (50/60 Hz)
Operating Voltage Range85 to 110% of rated supply voltage
Power ConsumptionApprox. 12 VA (at 240 VAC)/Approx. 2.5 W (at 240 VAC)
Time Ranges0.01 to 99.99 s

Omron AC DOWN Short Timer H5CN-YAN AC100-240 Technical Specifications:

SpecificationValue
Rated supply voltage100 to 240 VAC (50/60 Hz)
Operating voltage range85 to 110% of rated supply voltage
Power consumptionApprox. 12 VA (at 240 VAC)/Approx. 2.5 W (at 240 VAC)
Time ranges (Number of ranges)1
Time ranges0.01 to 99.99 s
Input methodContact: Contact open and short-circuit input No-contact: Open-collector transistor ON/OFF input
Output modesN: Power ON delay
Control output (Contact output)SPDT Resistive load: 3 A at 250 VAC (cosφ=1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Reset systemPower reset/External reset
Power resetMinimum power-opening time: 0.5 s
External reset and GateMinimum input signal width: 0.02 s Residual voltage: 2 V max.
Timer ModeUP display timer (increments form 0 to the set time)
Display method7-segment LED 4 digit
Character height10 mm
Ambient temperature (Storage)-10 to 55 ℃ (with no icing)
Ambient humidity Operating-25 to 65 ℃ (with no icing)
Ambient humidity range35 to 85%
Accuracy of operating timeReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Setting errorReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Influence of voltageReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Influence of temperatureReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between operating power circuit and control output circuit: 100 MΩ min. (at 500 VDC)
Dielectric strengthBetween current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and control output circuit: 2000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween operating power supply terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV
Noise ImmunityBetween operating power supply terminals: ±2 kV Square-wave noise by noise simulator
Static ImmunityMulfunction: 8 kV
Vibration ResistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock ResistanceDestruction: 300 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output)Electrical: 100,000 operations min. (3 A at 250 VAC resistive load) Mechanical: 10 million operations min.
Mounting methodFlush mounting / Surface mounting
External connection method8-pin round socket
Case colorLight gray (Munsell 5Y7/1)
Applicable socketP2CF-08, P2CF-08-E, P3G-08
Accessory (sold separately)Soft Cover: Y92A-48D Hard Cover: Y92A-48B Flush mounting adapter: Y92F-30
WeightApprox. 110 g
IndMALL Dealing in Omron AC DOWN Short Timer, H5CN-YAN AC100-240 at the best rates. Operational Specifications for H5CN-YAN AC100-240 are 100 to 240 VAC (50/60 Hz), 85 to 110% of rated supply voltage, 1, 0.01 to 99.99 s, N: Power ON delay, 7-segment LED 4 digit, 10 mm & -10 to 55 ℃ (with no icing). And It Delivers Flush mounting / Surface mounting, 8-pin round socket & Light gray (Munsell 5Y7/1). Unlock Exclusive Pricing with a Quote for your requirement of Omron AC DOWN Short Timer. Experience the advantage of our pricing and support against other Traders.