H5CX-L8E-N: Omron ICD 4 Digit SPDT Timer
Technical Specifications of Omron ICD 4 Digit SPDT Timer H5CX-L8E-N:
Spec | Value |
---|---|
Rated Supply Voltage | 100 to 240 VAC (50/60 Hz) |
Operating Voltage range | 85 to 110% of rated supply voltage |
Time Ranges | 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 min |
Power Consumption | Approx. 6.2 VA |
Omron ICD 4 Digit SPDT Timer H5CX-L8E-N Technical Specifications:
Specification | Value |
---|---|
Rated supply voltage | 100 to 240 VAC (50/60 Hz) |
Operating voltage range | 85 to 110% of rated supply voltage |
Power consumption | Approx. 6.2 VA |
Time ranges(Number of ranges | 10 |
Time ranges | 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 min |
Input method | - |
No-voltage input (Solid state input) | - |
No-voltage input (Applicable two-wire sensor) | - |
Voltage input | - |
Output modes | A-2: Power ON delay (Ⅱ) b: Repeat cycle (Ⅰ) E: Interval Z: ON/OFF-duty adjustable flicker toff: Flicker OFF start (Ⅰ) ton: Flicker ON start (Ⅰ) |
Control output (Solid state output) | Time-limit contact: SPDT, Instantaneous contact: SPDT Resistive load: 5 A at 250 VAC/30 VDC (cosφ = 1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Reset system | Power reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual reset |
Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode) |
Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) |
Display method | 7-segment negative transmissive LCD 4 digit |
Character height | Present value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green) |
Key protect method | Key protect Switch |
Memory backup method | EEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.) |
Ambient temperature (Operating) | -10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation) |
Ambient temperature (Storage) | -25 to 70 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) | 25 to 85% |
Accuracy of operating time | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
Setting error | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
Influence of voltage | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
Influence of temperature | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 1000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV |
Noise immunity | Between power terminals: ±1.5 kV square-wave noise by noise simulator, pulse width: 100 ns/1 µs, 1-ns rise |
Static immunity | Mulfunction: 8 kV, Destruction: 15 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy | Electrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 ℃) Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 ℃) |
Degree of protection | IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter) |
Mounting method | Flush mounting / Surface mounting |
External connection method | 8-pin round socket |
Case color | Black (Munsell N1.5) |
Attachment | - |
Accessory (sold separately) | Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B |
Weight | Main Unit: Approx. 115 g |
Mail Us for your needs in Omron ICD 4 Digit SPDT Timer, H5CX-L8E-N with budget-friendly prices. The Main Technical Parameters of H5CX-L8E-N include 100 to 240 VAC (50/60 Hz), 85 to 110% of rated supply voltage, Approx. 6.2 VA, 10, 7-segment negative transmissive LCD 4 digit, -, - & Key protect Switch. Additionally, it provides Black (Munsell N1.5), Flush mounting / Surface mounting & 8-pin round socket. Customize Your Experience with a Quote for your requirement of Omron ICD 4 Digit SPDT Timer. Experience the difference with our competitive pricing and superior support over other Suppliers.