Spec | Value |
---|---|
Classification | Preset counter |
Configuration | • 1-stage preset counter • Total and preset counter |
Power Supply Voltage | 100 to 240 VAC |
Power Consumption | Approx. 6.8 VA |
Omron 1-Stage Preset Counter H7CC-AS Technical Specifications:
Specification | Value |
---|---|
Classification | Preset counter |
Configuration | • 1-stage preset counter • Total and preset counter |
Power Supply Voltage | 100 to 240 VAC |
Mounting Method | Flush mounting or surface mounting |
External Connections | 11-pin socket |
input Signals | CP1, CP2, reset 1, and reset 2 |
Counter Output Mode | N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. |
Outputs | Transistor output (SPST) |
Digits | 6 digits -99999 to 999999 (-5 digits to +6 digits) |
Operating voltage fluctuation range | 85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%) |
Degree of protection | IEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used |
Maximum counting speed | 30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms) (selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2 |
Counter Input mode | Increment (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs) |
Auto-zero time/Startup time | 0.01 to 99.99 s |
Counter One-shot out put time | - |
Sensor waiting time | External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation) |
Counter Reset system | - |
Decimal point adjustment | Refer to the separate table for tachometer function ratings |
Tachometer | - |
Prescaling function | Yes (0.001 to 99.999) |
Sensor waiting time | 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) |
Input method | No-voltage (NPN) input/voltage (PNP) input (switchable) No-voltage inputs: ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input: High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) |
External power supply | 12 VDC (±10%), 100 mA (except for H7CC-A8@ models) Refer to Precautions for Correct Use on page 61 for details |
Control output | • Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) • Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max. |
Display | 7-segment, negative transmissive LCD Character height Count value: 10 mm (white) Set value: 6 mm (green) |
Memory backup | Non-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min. |
Operating temperature range | -10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation) |
Storage temperature range | -25 to 70°C (with no icing or condensation) |
Operating humidity range | 25% to 85% |
Case Color | Black (N1.5) |
Send Your Inquiry for Omron 1-Stage Preset Counter, H7CC-AS with cost-effective solutions. Essential Technical Specs of H7CC-AS cover N, F, C, R, K-1, P, Q, A, K-2, D, L, and H., CP1, CP2, reset 1, and reset 2, 11-pin socket, Flush mounting or surface mounting. It also delivers Approx. 6.8 VA, 100 to 240 VAC, Preset counter. Capture the Best Deal with a Quote for your requirement of Omron 1-Stage Preset Counter. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.