H7ET-NFV-B: Omron Non-Backlight Time Counter

Technical Specifications of Omron Non-Backlight Time Counter H7ET-NFV-B:

SpecValue
FunctionTime Counter
Time Counter RangesIncrement (UP)
Counter Time Ranges0.0 h to 999999.9 h/0.0 h to 3999 d 23.9 h (selectable)
Time counter Set value read selector±100 ppm (25 ℃)
Time counter Reset systemExternal and manual reset

Omron Non-Backlight Time Counter H7ET-NFV-B Technical Specifications:

SpecificationValue
FunctionTime Counter
Time counter rangesIncrement (UP)
Counter Time ranges0.0 h to 999999.9 h/0.0 h to 3999 d 23.9 h (selectable)
Time counter Set value read selector±100 ppm (25 ℃)
Time counter Reset systemExternal and manual reset
Input signalCount input, Reset
Input methodFree voltage input
No-voltage input (No-contact input)/ Voltage inputHight level: 24 to 240 VAC/VDC Low level: 0 to 2.4 VAC/VDC Short-circuit (ON) impedance: 10 kΩ max. Open circuit impedance: 750 kΩ min.
External/Manual Reset time20 ms
Display methodLCD
Display Digits7 digit
Display Character height8.6 mm (Black)
Display Zero suppressionEquipped
Ambient temperature (Operating)-10 to 55 ℃ (with no freezing or condensation)
Ambient temperature (Storage)-25 to 65 ℃ (with no freezing or condensation)
Ambient humidity (Operating)25 to 85 %
Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between timer input terminals and reset terminals: 100 MΩ min. (at 500 VDC)
Dielectric withstand voltageBetween reset terminals and exposed non-current-carrying metal parts: 2200 VAC 50/60 Hz 1 min Between timer input terminals and exposed non-current-carrying metal parts: 3700 VAC 50/60 Hz 1 min Between timer input terminals and reset terminals: 2200 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween current carrying terminals and exposed non-current carrying metal parts: 4.5 kV Between timer input terminals and reset terminals: 3 kV
Noise immunityBetween reset terminals: ±500 V Between timer input terminals: ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity±8 kV (malfunction)
Vibration resistanceDestruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.15 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 300 m/s2, 3 times each in 6 directions Malfunction: 200 m/s2, 3 times each in 6 directions
Degree of protectionCase front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors)
External connection methodScrew terminal
Case colorBlack (Munsell N1.5)
WeightApprox. 60 g
"IndMALL Dealing in H7ET-NFV-B, at the best rates. Operational Specifications for are Omron Non-Backlight Time Counter H7ET-NFV-B Technical Specifications:, 0.0 h to 999999.9 h/0.0 h to 3999 d 23.9 h (selectable), Increment (UP) , Hight level: 24 to 240 VAC/VDC Low level: 0 to 2.4 VAC/VDC Short-circuit (ON) impedance: 10 kΩ max. Open circuit impedance: 750 kΩ min.. And It Delivers Free voltage input, Count input, Reset, ±100 ppm (25 ℃). Unlock Exclusive Pricing with a Quote for your requirement of H7ET-NFV-B. Experience the advantage of our pricing and support against other Traders."