MY2 AC12: Omron 12V Relay in Chennai
The technical specifications for the Omron 12V Relay MY2 AC12:
- Degree of protection: Closed type (cover)
- Terminal structure: Plug-in terminal
- Contact form: DPDT
- Mounting method: Socket
- Coil resistance: 46 Ω
- Maximum voltage: 110 % (23 ℃)
- Contact method: Single
Omron 12V Relay MY2 AC12 Technical Specifications:
Degree of protection | Closed type (cover) |
Terminal structure | Plug-in terminal |
Coil ratings | 12 VAC 50 Hz 106.5 mA 12 VAC 60 Hz 91 mA |
Coil resistance | 46 Ω |
Operate voltage (Set voltage) | 80% max. |
Release voltage (Reset voltage) | 30 % min. |
Power consumption | Approx. 0.9 to 1.3 VA 60 Hz |
Contact rated load | 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 24 VDC 5 A (Resistive load) 24 VDC 2 A (Inductive load (L/R = 7 ms)) |
Max. contact voltage | 250 VAC 125 VDC |
Max. Contact Current | AC: 5 A DC: 5 A |
Maximum switching power | 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) |
Contact method | Single |
Contact form | DPDT |
Contact resistance | 50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
Contact material | Ag |
Operating time | 20 ms max. (With rated operating power applied, not including contact bounce) |
Reset time | 20 ms max. (With rated operating power applied, not including contact bounce) |
Maximum operating frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
Ambient temperature (Operating) | -55 to 70 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) | 5 to 85% |
Mounting method | Socket |
Are you Looking for a cost-effective Omron MY2 AC12 Relay in Chennai? The Omron 12V Relay is an excellent option. It features a closed cover for safety and plug-in terminals for easy installation. This relay operates with a 12 VAC coil, consuming about 0.9 to 1.3 VA at 60 Hz. It’s suitable for both AC and DC loads, handling up to 250 VAC and 5 A. Available at IndMALL at competitive prices.