The technical specifications for the Omron Relay DPDT 12VDC Coil MY2F DC12:
- Degree of protection: Closed type (cover)
- Coil ratings: 12 VDC 75 mA
- Contact form: DPDT
- Mounting method: Case-surface mounting
- Power consumption: Approx. 0.9 W
- Maximum voltage: 110 % (23 ℃)
- Contact method: Single
Omron Relay DPDT 12VDC Coil MY2F DC12 Technical Specifications:
Degree of protection | Closed type (cover) |
No.of Poles | 2-Pole |
Coil ratings Operate /Release | 12 VDC 75 mA |
Coil resistance | 160 Ω |
Operate voltage (Set voltage) | 80% max. |
Release voltage (Reset voltage) | 10 % min. |
Power consumption Operate / Release | Approx. 0.9 W |
Contact rated load | 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 24 VDC 5 A (Resistive load) 24 VDC 2 A (Inductive load (L/R = 7 ms)) |
Max. contact voltage | 250 VAC 125 VDC |
Max. Contact Current | AC: 5 A DC: 5 A |
Maximum switching power | 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) |
Contact method | Single |
Contact form | DPDT |
Contact resistance | 50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
Contact material | Ag |
Operating time | 20 ms max. (With rated operating power applied, not including contact bounce) |
Reset time | 20 ms max. (With rated operating power applied, not including contact bounce) |
Maximum operating frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
Ambient temperature (Operating) | -55 to 70 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) | 5 to 85% |
Mounting method | Case-surface mounting |
If you are in Chennai and looking for a reliable relay at a great price, check out IndMALL Automation’s Omron MY2F DC12 Relay DPDT 12VDC Coil. This relay offers a closed cover for protection, operates with a 12 VDC coil at 75 mA, and is perfect for case-surface mounting. It’s designed to handle loads up to 5 A for both AC and DC, with a power consumption of about 0.9 W. Ideal for various applications, it ensures quick response and durability in different environments.