MY2K DC24: Omron MY2K Latching Relay in Chennai
The technical specifications for the Omron MY2K Latching Relay MY2K DC24:
- Degree of protection: Closed type (cover)
- Terminal structure: Plug-in terminal
- Contact form: DPDT
- Mounting method: Socket
- Coil ratings Operate/Release: 24 VDC 52 mA/25 mA
- Maximum voltage: 110 % (23 ℃)
- Min. set-reset signal width: 30 ms
Omron MY2K Latching Relay MY2K DC24 Technical Specifications:
Degree of protection | Closed type (cover) |
Terminal structure | Plug-in terminal |
Coil ratings Operate /Release | 24 VDC 52 mA / 24 VDC 25 mA |
Coil resistance | Operate: 470 Ω Release: 940 Ω |
Operate voltage (Set voltage) | 80% max. |
Release voltage (Reset voltage) | 80% max |
Power consumption Operate / Release | Approx. 1.3 W / Approx. 0.6 W |
Contact rated load | 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ = 0.4)) 24 VDC 3 A (Resistive load) 24 VDC 1.5 A (Inductive load (L/R = 7 ms)) |
Max. contact voltage | 250 VAC 125 VDC |
Max. Contact Current | AC: 3 A DC: 3 A |
Maximum switching power | 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) |
Contact method | Single |
Contact form | DPDT |
Contact resistance | 50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
Min. set-reset signal width | 30 m |
Operating time | 15 ms max. (With rated operating power applied, not including contact bounce) |
Reset time | 15 ms max. (With rated operating power applied, not including contact bounce) |
Maximum operating frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
Ambient temperature (Operating) | -55 to 60 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) | 5 to 85% |
Mounting method | Socket |
Looking for details on the Omron MY2K Latching Relay MY2K DC24? It’s a powerful relay with a 24 VDC coil that operates at 52 mA and releases at 25 mA. Designed as a DPDT (Double Pole Double Throw) with single contact method, it features contacts plated with gold and silver. This relay can handle up to 220 VAC and 3 A for resistive loads, 0.8 A for inductive loads with a power factor of 0.4, and 24 VDC up to 3 A for resistive and 1.5 A for inductive loads with an L/R of 7 ms. It has plug-in terminals, is enclosed in a protective cover, and mounts easily on a socket. IndMALL provides best quotes in Chennai.