NX-OC4633: Omron PLC NO Relay Output Unit
Technical Specifications of Omron PLC NO Relay Output Unit NX-OC4633:
Spec | Value |
---|---|
Number of Model points | 8 points |
Internal I/O common | Relay type: N.O. |
Power supply voltage | 24 VDC (20.4 to 28.8 VDC) |
Unit power consumption | 5.80 W max. |
Omron PLC NO Relay Output Unit NX-OC4633 Technical Specifications:
Specification | Value |
---|---|
Number of Model points | 8 points |
Internal I/O common | Relay type: N.O. |
Rated input voltage | 250 VAC/2 A (cosφ=1), 250 VAC/ 2 A (cosφ=0.4), 24 VDC/2 A, 4 A/Unit |
I/O refreshing method | Free-Run refreshing |
ON/OFF response time | 15 ms max./ 15 ms max. |
Dimensions (mm) | 72 × 100 × 90 mm (W×H×D) |
Power supply voltage | 24 VDC (20.4 to 28.8 VDC) |
Unit power consumption | 5.80 W max. |
Shock resistance | Conforms to IEC 60068-2-27. 147 m/s2, 3 times in X, Y, and Z directions |
Vibration resistance | Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total). |
Noise immunity | 2 kV on power supply line (Conforms to IEC 61000-4-4.) |
Pollution degree | 2 or less: Meets IEC 61010-2-201. |
Ambient operating temperature | 0 to 55°C |
Ambient operating humidity | 10% to 95% (with no condensation) |
Ambient storage temperature | -25 to 70°C (excluding battery) |
Weight | 390 g max. |
Send Your Inquiry for Omron PLC NO Relay Output Unit NX-OC4633 with cost-effective solutions. Essential Technical Specs of NX-OC4633 are 8 points with internal I/O common Relay type: N.O. and operates on a rated input voltage of 250 VAC/2 A (cosφ=1), 250 VAC/ 2 A (cosφ=0.4), 24 VDC/2 A, 4 A/Unit. It supports both Free-Run refreshing methods, with an ON/OFF response time of 15 ms max./ 15 ms max. The unit's dimensions are 72 × 100 × 90 mm (W×H×D), and it requires a power supply voltage of 24 VDC (20.4 to 28.8 VDC) with a maximum power consumption of 5.80 W max. It also meets noise immunity standards of 2 kV on power supply line (Conforms to IEC 61000-4-4.) and has a pollution degree of 2 or less: Meets IEC 61010-2-201. The ambient operating temperature ranges from 0 to 55°C, with humidity from 10% to 95% (with no condensation), and storage temperatures from -25 to 70°C (excluding battery). Capture the Best Deal with a Quote for your requirement of Omron PLC NO Relay Output Unit. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.