S8VS-09024BES-F: Omron 90W 3.75A with Total Run Time Monitor
Technical Specifications of Omron 90W 3.75A with Total Run Time Monitor S8VS-09024BES-F:
Spec | Value |
---|---|
Power Rating | 90 W |
Output Voltage | 24 VDC |
Connection | Terminal blocks |
Terminal Type | Screwless Terminal |
Omron 90W 3.75A with Total Run Time Monitor S8VS-09024BES-F Technical Specifications:
Specification | Value |
---|---|
Power rating | 90 W |
Output voltage | 24 VDC |
Connection | Terminal blocks |
Terminal type | Screwless Terminal |
Mounting | DIN track |
Efficiency | 83% typ. (at 100 VAC input) 85% typ. (at 200 VAC input) |
Rated input voltage | 100 to 240 VAC |
Input Frequency | 50/60Hz (47 to 450 Hz) |
Rated input current | 2.3 A max., 1.9 A typ. (at 100 VAC input) 1.4 A max., 1.2 A typ. (at 200 VAC input) |
Input Leakage current | 0.5 mA max. (at 100 VAC input) 1.0 mA max. (at 200 VAC input) |
Rated output current | 3.75 A |
Output voltage variable range | -10 to +15% With V.ADJ |
Start-up time | 660 ms typ. (at 100 VAC input) 420 ms typ. (at 200 VAC input) |
Hold time | 28 ms typ. (at 100 VAC input) 136 ms typ. (at 200 VAC input) |
Output indicator | Yes (color: green) |
Vibration resistance | 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
Shock resistance | 150 m/s2, in each 6 directions 3 times |
Ambient temperature (Operating) | -10 to 60 ℃ |
Ambient temperature (Storage) | -25 to 65 ℃ |
Ambient humidity (OperatingStorage) | 25 to 85% |
Cooling fan | No |
Degree of protection | - |
Weight | 490 g max. |
Obtain A Quote for Omron 90W 3.75A with Total Run Time Monitor, S8VS-09024BES-F with exclusive offers. In-depth Technical Analysis of S8VS-09024BES-F includes 90 W, 24 VDC, Terminal blocks, Screwless Terminal, DIN track, 83% typ. (at 100 VAC input)
85% typ. (at 200 VAC input), 100 to 240 VAC & 50/60Hz (47 to 450 Hz). Moreover, it features 2.3 A max., 1.9 A typ. (at 100 VAC input)
1.4 A max., 1.2 A typ. (at 200 VAC input), 0.5 mA max. (at 100 VAC input)
1.0 mA max. (at 200 VAC input), 3.75 A, -10 to +15% With V.ADJ, 660 ms typ. (at 100 VAC input)
420 ms typ. (at 200 VAC input), 28 ms typ. (at 100 VAC input)
136 ms typ. (at 200 VAC input), Yes (color: green), 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours, 150 m/s2, in each 6 directions 3 times, -10 to 60 ℃, -25 to 65 ℃. Don't Miss Out on a Quote for your requirement of Omron 90W 3.75A with Total Run Time Monitor. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.