S8VS-12024BE: Omron 120W 24V Monitor No Alarm Output
Technical Specifications of Omron 120W 24V Monitor No Alarm Output S8VS-12024BE:
Spec | Value |
---|---|
Power Rating | 120 W |
Output Voltage | 24 VDC |
Connection | Terminal blocks |
Terminal Type | Screw Terminal |
Omron 120W 5A Total Run Time Monitor S8VS-12024BE Technical Specifications:
Specification | Value |
---|---|
Power rating | 120 W |
Output voltage | 24 VDC |
Connection | Terminal blocks |
Terminal type | Screw Terminal |
Mounting | DIN track |
Efficiency | 83% typ. (at 100 VAC input) 85% typ. (at 200 VAC input) |
Rated input voltage | 100 to 240 VAC |
Input Frequency | 50/60Hz (47 to 450 Hz) |
Rated input current | 1.9 A max., 1.5 A typ. (at 100 VAC input) 1.1 A max., 0.72 A typ. (at 200 VAC input) |
Input Leakage current | 0.5 mA max. (at 100 VAC input) 1.0 mA max. (at 200 VAC input) |
Rated output current | 5 A |
Output voltage variable range | -10 to +15% With V.ADJ |
Start-up time | 650 ms typ. (at 100 VAC input) 520 ms typ. (at 200 VAC input) |
Hold time | 56 ms typ. (at 100 VAC input) 56 ms typ. (at 200 VAC input) |
Output indicator | Yes (color: green) |
Vibration resistance | 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
Shock resistance | 150 m/s2, in each 6 directions 3 times |
Ambient temperature (Operating) | -10 to 60 ℃ |
Ambient temperature (Storage) | -25 to 65 ℃ |
Ambient humidity (OperatingStorage) | 25 to 85% |
Cooling fan | No |
Degree of protection | - |
Weight | 550 g max. |
Please speak to our Technical Engineer Omron 120W 24V Monitor No Alarm Output, S8VS-12024BE with exclusive offers. In-depth Technical Analysis of S8VS-12024BE includes 120 W, 24 VDC, Terminal blocks, Screw Terminal, DIN track, 83% typ. (at 100 VAC input)
85% typ. (at 200 VAC input), 100 to 240 VAC & 50/60Hz (47 to 450 Hz). Moreover, it features 1.9 A max., 1.5 A typ. (at 100 VAC input)
1.1 A max., 0.72 A typ. (at 200 VAC input), 0.5 mA max. (at 100 VAC input)
1.0 mA max. (at 200 VAC input), 5 A, -10 to +15% With V.ADJ, 650 ms typ. (at 100 VAC input)
520 ms typ. (at 200 VAC input), 56 ms typ. (at 100 VAC input)
56 ms typ. (at 200 VAC input), Yes (color: green), 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours, 150 m/s2, in each 6 directions 3 times, -10 to 60 ℃, -25 to 65 ℃. Don't Miss Out on a Quote for your requirement of Omron 120W 24V Monitor No Alarm Output. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.