KFD2-SLD-Ex2-1545-Y1: P&F 2-Channel, Test Pulse Immunity Solenoid Driver
Technical Specifications of P&F 2-Channel, Test Pulse Immunity Solenoid Driver KFD2-SLD-Ex2-1545-Y1:
Spec | Value |
---|---|
Signal type | Digital Output |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) |
Connection | screw terminals |
Output current | 45 mA |
P&F 2-Channel, Test Pulse Immunity Solenoid Driver KFD2-SLD-Ex2-1545-Y1 Technical Specifications:
Specification | Value |
---|---|
Signal type | Digital Output |
Safety Integrity Level (SIL) | - |
Systematic capability (SC) | - |
Supply Connection | Power Rail or terminals 14+, 15- |
Rated voltage | 18... 30 V DC |
Rated current | - |
Power dissipation | - |
Power consumption | max. 3.5 W at 45 mA output current |
Connection side (Input) | control side |
Connection (Input) | terminals 7, 8, 9 |
Signal Level | loop powered 1-signal: 18 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited to 5 mA) 0-signal: 0 ... 5 V DC |
Inrush current(Input) | ≤ 200 mA after 100 µs |
Connection side (Output) | field side |
Connection (Output) | channel 1: terminals 1+, 2-, 3- channel 2: terminals 4+, 5-, 6- |
Internal resistor | approx. 167 Ω |
Current | 45 mA |
Voltage | ≥ 15 V |
Output current | 45 mA |
Switching frequency | - |
Display elements | LEDs |
Control elements | DIP switch |
Labeling | space for labeling at the front |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) |
Connection | screw terminals |
Mounting | on 35 mm DIN mounting rail |
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) , both channels configured in the bus powered mode of operation -40 ... 60 °C (-40 ... 140 °F) , all other configurations |
Degree of protection | IP20 |
Mass | approx. 150 g |
IndMALL Automation Dealing offers P&F 2-Channel, Test Pulse Immunity Solenoid Driver KFD2-SLD-Ex2-1545-Y1 at attractive prices. Key Technical Features of KFD2-SLD-Ex2-1545-Y1, features digital output and operates with a power rail or bus-powered input voltage of 18-30 V DC, with a maximum power consumption of 3.5 W at 45 mA output current. The control side connects via terminals 7, 8, 9, supporting both loop-powered (1-signal: 18-30 V DC, 0-signal: 0-5 V DC) and bus-powered (1-signal: 15-30 V DC, 0-signal: 0-5 V DC) configurations. The device supports currents up to 200 mA after 100 µs.
The field side connects via channel 1 (terminals 1+, 2-, 3-) and channel 2 (terminals 4+, 5-, 6-), with a resistance of approximately 167 Ω and a typical current of 45 mA at ≥ 15 V. The unit includes LED indicators, a DIP switch, and space for labeling at the front. Dimensions are 20 x 119 x 115 mm, and it mounts on a 35 mm DIN rail using screw terminals. It operates in temperatures ranging from -40 to 70 °C (both channels in bus-powered mode) and -40 to 60 °C (all other configurations), with an IP20 rating, and weighs approximately 150 g. Navigate Your Needs with a Quote for your requirement of P&F 2-Channel, Test Pulse Immunity Solenoid Driver. We excel in offering more cost-effective and supportive solutions than other Competitors.