Technical Specifications of Phoenix 230 V AC Input Voltage Relay Socket PLC-BSC-230UC/21/SO46 2980335:

SpecValue
Product TypeRelay socket
Connection MethodScrew connection
Screw ThreadM3
Mounting TypeDIN rail mounting

Phoenix 230 V AC Input Voltage Relay Socket PLC-BSC-230UC/21/SO46, 2980335 Technical Specifications:

SpecificationValue
Product typeRelay socket
Product familyPLC-INTERFACE
Nominal voltage UN-
Nominal current IN-
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Width6.2 mm
Height80 mm
Depth Retaining bracket-
Colorgray (RAL 7042)
Ambient temperature (operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Mounting typeDIN rail mounting
Mounting positionany
ApplicationFilter to prevent interference
Protective circuitRCV circuit
Nominal input voltage UN230 V AC
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm
Status displayLED
Depth94 mm
Flammability rating according to UL 94V0 (Housing)
Enclosure LowRequired protection according to the Rules shall be provided upon installation on board
Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive
Diameter-
Compatible componentsMiniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1
Input voltage range in reference to UN0.8 ... 1.1
Typical input current at UN8.8 mA (50 Hz)
Typical response time6 ms
Typical release time10 ms
Typical release voltage80 V AC
Operating voltage displayYellow LED
Maximum switching voltage253 V AC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage24 V AC
Limiting continuous current0.75 A
Voltage drop at max. limiting continuous current< 1 V AC
Output circuit2-conductor, floating
Maximum inrush current30 A (10 ms)
Leakage current< 1 mA
Phase angle cos phi min0.5
Max. load value4.5 A2s
Insulation-
Overvoltage category-
Test voltage (Winding/contact)-
Test voltage ()-
Rated insulation voltage-
Rated surge voltage-
Degree of protection-
Standards/regulations-
Rated control circuit supply voltage US-
Voltage range with reference to US-
Rated control supply current IS-
Rated actuating voltage UC-
Voltage range with reference to UC-
Rated actuating current IC-
Surge voltage protection-
Switching level 1 signal ("H") (TTL signal)-
Switching level 0 signal ("L") (TTL signal)-
Transmission frequency Test voltage relay winding/relay contact-
Switching threshold "0" signal, voltage-
Please speak to our Technical Engineer for Phoenix 230 V AC Input Voltage Relay Socket PLC-BSC-230UC/21/SO46 part no: 2980335 at attractive prices. Technical Specs Summary of PLC-BSC-230UC/21/SO46, 2980335 includes Product family PLC-INTERFACE, designed for versatile industrial applications. This sensor features a reliable Screw connection method, accommodating conductor cross sections of 0.14 mm² ... 2.5 mm², whether rigid or flexible 0.14 mm² ... 2.5 mm². The sensor has compact dimensions, with a width of 6.2 mm and a height of 80 mm, making it suitable for space-constrained installations. The housing is finished in gray (RAL 7042), ensuring a professional appearance. It operates efficiently within ambient temperatures ranging from -40 °C ... 55 °C, both during operation and storage. The sensor is designed for easy DIN rail mounting, allowing for flexible mounting positions in any orientation. Match Your Needs with a Quote for your requirement of Phoenix 230 V AC Input Voltage Relay Socket. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.