Phoenix REL-IR2/LDP- 48DC/2X21 (2903661) | Inquire Now
+91 79955 44066 sales@indmall.in

REL-IR2/LDP- 48DC/2X21: 2903661 - Phoenix 48 V DC Input Voltage Single Relays

Phoenix Contact REL-IR2/LDP- 48DC/2X21 2903661

Technical Specifications of Phoenix 48 V DC Input Voltage Single Relays REL-IR2/LDP- 48DC/2X21 2903661:

SpecValue
Product TypeSingle relay
Mechanical service lifeapprox. 2x 107 cycles
Nominal input voltage UN48 V DC
Input voltage range37.4 V DC ... 93.6 V DC

Phoenix 48 V DC Input Voltage Single Relays REL-IR2/LDP- 48DC/2X21, 2903661 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service lifeapprox. 2x 107 cycles
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree3 (Rated voltage of 230 V)
Service life electricalsee diagram
Maximum power dissipation for nominal condition1.06 W
Test voltage (Winding/contact)2.5 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)2.5 kVrms (50 Hz, 1 min., changeover contact/changeover contact)
Rated insulation voltage250 V AC
Rated surge voltage4 kV
Nominal input voltage UN48 V DC
Input voltage range37.4 V DC ... 93.6 V DC
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN22 mA
Typical response time14 ms
Coil voltage-
Status displayLED (yellow)
Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (At 24 mA)
Limiting continuous current12 A
Maximum inrush current30 A (20 ms, N/O contacts)
Min. switching current5 mA (at 24 V)
Interrupting rating (ohmic load) max.288 W (at 24 V DC)
Connection methodPlug-in connection
Width21.2 mm
Height27.5 mm
Depth35.6 mm
Degree of protectionRT I
Degree of protection (Installation location)-
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsIEC 60664
Mounting type-
Mounting positionany
Mains frequency-
Typical release time range-
Coil resistance-
Switching capacity-
Motor load according to UL 5081/2 HP, 240 V AC
Input power dissipation for UN-
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Give Us a Call for Phoenix 48 V DC Input Voltage Single Relays REL-IR2/LDP- 48DC/2X21 part no: 2903661 at the lowest pricing. In-depth Technical Analysis of REL-IR2/LDP- 48DC/2X21, 2903661 feature mechanical service life of approx. 2x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 48 V DC, with an input voltage range of 37.4 V DC ... 93.6 V DC. The typical input current at UN is 22 mA with a response time of 13 ms. The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 5 V (At 24 mA). It has a limiting continuous current of 12 A, with a maximum inrush current of 30 A (20 ms, N/O contacts), and a minimum switching current of 5 mA (at 24 V). The interrupting rating for ohmic loads is 288 W (at 24 V DC). The connection method is via a Plug-in connection, with a degree of protection rated at RT I. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 70 °C. Elevate Your Project with a Quote for your requirement of Phoenix 48 V DC Input Voltage Single Relays. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.