Phoenix REL-MR-110DC/21-21 (2961202) | Contact for Pricing
+91 79955 44066 sales@indmall.in

REL-MR-110DC/21-21: 2961202 - Phoenix Contact 110 V DC Voltage Single Relay

Phoenix Contact REL-MR-110DC/21-21 2961202

Technical Specifications of Phoenix Contact 110 V DC Voltage Single Relay REL-MR-110DC/21-21 2961202:

SpecValue
Product TypeSingle relay
Mechanical service life3x 107 cycles
Nominal input voltage UN110 V DC
Input voltage range71.5 V DC ... 272.8 V DC

Phoenix Contact 110 V DC Voltage Single Relay REL-MR-110DC/21-21, 2961202 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service life3x 107 cycles
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree3
Service life electricalsee diagram
Maximum power dissipation for nominal condition0.45 W
Test voltage (Winding/contact)5 kV AC (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)-
Rated insulation voltage-
Rated surge voltage-
Nominal input voltage UN110 V DC
Input voltage range71.5 V DC ... 272.8 V DC
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN4.1 mA
Typical response time3 ms
Coil voltage-
Status display-
Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (at 10 mA)
Limiting continuous current8 A
Maximum inrush current25 A (20 ms)
Min. switching current10 mA (At 5 V)
Interrupting rating (ohmic load) max.190 W (at 24 V DC)
Connection methodPlug / solder connection
Width12.7 mm
Height29 mm
Depth15.7 mm
Degree of protectionRT III
Degree of protection (Installation location)-
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsIEC 60664
Mounting type-
Mounting positionany
Mains frequency-
Typical release time range-
Coil resistance26600 Ω ±15 % (at 20 °C)
Switching capacity2 A (at 24 V, DC13)
Motor load according to UL 5081/4 HP, 120 V AC
Input power dissipation for UN-
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Send Your Inquiry for Phoenix Contact 110 V DC Voltage Single Relay REL-MR-110DC/21-21 part no: 2961202 with cost-effective solutions. Essential Technical Specs of REL-MR-110DC/21-21, 2961202 are mechanical service life of 3x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 110 V DC, with an input voltage range of 71.5 V DC ... 272.8 V DC. The typical input current at UN is 4.1 mA with a response time of 7 ms. The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 5 V (at 10 mA). It has a limiting continuous current of 8 A, with a maximum inrush current of 25 A (20 ms), and a minimum switching current of 10 mA (At 5 V). The interrupting rating for ohmic loads is 190 W (at 24 V DC). The connection method is via a Plug / solder connection, with a degree of protection rated at RT III. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 85 °C. Capture the Best Deal with a Quote for your requirement of Phoenix Contact 110 V DC Voltage Single Relay. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.