REL-MR-120AC/21HC AU: 2961516 - Phoenix Input Voltage 120 V Single Relay

Phoenix Contact REL-MR-120AC/21HC AU 2961516

Technical Specifications of Phoenix Input Voltage 120 V Single Relay REL-MR-120AC/21HC AU 2961516:

SpecValue
Product TypeSingle relay
Mechanical service life1x 107 cycles
Nominal input voltage UN120 V AC
Input voltage range93.6 V AC ... 186 V AC

Phoenix Input Voltage 120 V Single Relay REL-MR-120AC/21HC AU, 2961516 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service life1x 107 cycles
Insulation-
Overvoltage categoryIII
Pollution degree3
Service life electricalsee diagram
Maximum power dissipation for nominal condition0.84 W
Test voltage (Winding/contact)5 kV AC (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)-
Rated insulation voltage-
Rated surge voltage-
Nominal input voltage UN120 V AC
Input voltage range93.6 V AC ... 186 V AC
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN7 mA (at 50 Hz)
Typical response time-
Coil voltage-
Status display-
Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage12 V (at 10 mA)
Limiting continuous current16 A
Maximum inrush current50 A (20 ms)
Min. switching current10 mA (at 12 V)
Interrupting rating (ohmic load) max.384 W (at 24 V DC)
Connection methodPlug / solder connection
Width12.7 mm
Height29 mm
Depth15.7 mm
Degree of protection-
Degree of protection (Installation location)-
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsIEC 60664
Mounting type-
Mounting positionany
Mains frequency50/60 Hz
Typical release time range2 ms ... 9 ms (depending on phase relation)
Coil resistance8100 Ω ±15 % (at 20 °C)
Switching capacity2 A (at 24 V, DC13)
Motor load according to UL 508-
Input power dissipation for UN-
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Ask for the Pricing of Phoenix Input Voltage 120 V Single Relay REL-MR-120AC/21HC AU part no: 2961516 at unbeatable prices. Detailed Specifications of REL-MR-120AC/21HC AU, 2961516 feature mechanical service life of 1x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 120 V AC, with an input voltage range of 93.6 V AC ... 186 V AC. The typical input current at UN is 7 mA (at 50 Hz) with a response time of 3 ms ... 12 ms (depending on phase relation). The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 12 V (at 10 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 50 A (20 ms), and a minimum switching current of 10 mA (at 12 V). The interrupting rating for ohmic loads is 384 W (at 24 V DC). The connection method is via a Plug / solder connection, with a degree of protection rated at -. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 85 °C. Now's the Time to Secure a Quote for your requirement of Phoenix Input Voltage 120 V Single Relay. We're committed to offering more favorable pricing and more responsive support than other Traders.