REL-MR-120AC/21HC/MS: 2987901 - Phoenix Input Voltage 120V Single Relay
Technical Specifications of Phoenix Input Voltage 120V Single Relay REL-MR-120AC/21HC/MS 2987901:
Spec | Value |
---|---|
Product Type | Single relay |
Mechanical service life | 5x 106 cycles |
Nominal input voltage UN | 120 V AC |
Input voltage range | 93.6 V AC ... 174 V AC |
Phoenix Input Voltage 120V Single Relay REL-MR-120AC/21HC/MS, 2987901 Technical Specifications:
Specification | Value |
---|---|
Product type | Single relay |
Mechanical service life | 5x 106 cycles |
Insulation | - |
Overvoltage category | - |
Pollution degree | - |
Service life electrical | see diagram |
Maximum power dissipation for nominal condition | 0.84 W |
Test voltage (Winding/contact) | 5 kV AC (50 Hz, 1 min., winding/contact) |
Test voltage (Changeover contact/changeover contact) | - |
Rated insulation voltage | - |
Rated surge voltage | - |
Nominal input voltage UN | 120 V AC |
Input voltage range | 93.6 V AC ... 174 V AC |
Drive and function | monostable |
Drive (polarity) | non-polarized |
Typical input current at UN | 7 mA |
Typical response time | - |
Coil voltage | - |
Status display | - |
Contact switching type | 1 changeover contact |
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC |
Minimum switching voltage | 12 V (at 10 mA) |
Limiting continuous current | 16 A |
Maximum inrush current | 32 A (20 ms) |
Min. switching current | 10 mA (at 12 V) |
Interrupting rating (ohmic load) max. | 4000 VA (for 250 V AC) |
Connection method | Plug / solder connection |
Width | 12.7 mm |
Height | 29 mm |
Depth | 25 mm |
Degree of protection | - |
Degree of protection (Installation location) | - |
Ambient temperature (operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Standards/regulations | EN 61810-1 |
Mounting type | - |
Mounting position | - |
Mains frequency | 50/60 Hz |
Typical release time range | 2 ms ... 8 ms (depending on phase relation) |
Coil resistance | - |
Switching capacity | 2 A (at 24 V, DC13) |
Motor load according to UL 508 | 1/2 HP, 120 V AC (N/O contact) |
Input power dissipation for UN | - |
3-phase motor load | - |
Product family | - |
Relay type | - |
Test voltage () | - |
Degree of protection (Relay) | - |
Inrush current, minimum | - |
Non-operate voltage | - |
Safe operate voltage | - |
Test voltage (N/O contact / N/O contact) | - |
Give Us a Call for Phoenix Input Voltage 120V Single Relay REL-MR-120AC/21HC/MS part no: 2987901 at the lowest pricing. In-depth Technical Analysis of REL-MR-120AC/21HC/MS, 2987901 feature mechanical service life of 5x 106 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 120 V AC, with an input voltage range of 93.6 V AC ... 174 V AC. The typical input current at UN is 7 mA with a response time of 3 ms ... 12 ms (depending on phase relation). The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 12 V (at 10 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 32 A (20 ms), and a minimum switching current of 10 mA (at 12 V). The interrupting rating for ohmic loads is 4000 VA (for 250 V AC). The connection method is via a Plug / solder connection, with a degree of protection rated at -. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 70 °C. Elevate Your Project with a Quote for your requirement of Phoenix Input Voltage 120V Single Relay. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.