Phoenix REL-MR-120AC/21HC/MS (2987901) | Call for Pricing
+91 79955 44066 sales@indmall.in

REL-MR-120AC/21HC/MS: 2987901 - Phoenix Input Voltage 120V Single Relay

Phoenix Contact REL-MR-120AC/21HC/MS 2987901

Technical Specifications of Phoenix Input Voltage 120V Single Relay REL-MR-120AC/21HC/MS 2987901:

SpecValue
Product TypeSingle relay
Mechanical service life5x 106 cycles
Nominal input voltage UN120 V AC
Input voltage range93.6 V AC ... 174 V AC

Phoenix Input Voltage 120V Single Relay REL-MR-120AC/21HC/MS, 2987901 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service life5x 106 cycles
Insulation-
Overvoltage category-
Pollution degree-
Service life electricalsee diagram
Maximum power dissipation for nominal condition0.84 W
Test voltage (Winding/contact)5 kV AC (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)-
Rated insulation voltage-
Rated surge voltage-
Nominal input voltage UN120 V AC
Input voltage range93.6 V AC ... 174 V AC
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN7 mA
Typical response time-
Coil voltage-
Status display-
Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage12 V (at 10 mA)
Limiting continuous current16 A
Maximum inrush current32 A (20 ms)
Min. switching current10 mA (at 12 V)
Interrupting rating (ohmic load) max.4000 VA (for 250 V AC)
Connection methodPlug / solder connection
Width12.7 mm
Height29 mm
Depth25 mm
Degree of protection-
Degree of protection (Installation location)-
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsEN 61810-1
Mounting type-
Mounting position-
Mains frequency50/60 Hz
Typical release time range2 ms ... 8 ms (depending on phase relation)
Coil resistance-
Switching capacity2 A (at 24 V, DC13)
Motor load according to UL 5081/2 HP, 120 V AC (N/O contact)
Input power dissipation for UN-
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Give Us a Call for Phoenix Input Voltage 120V Single Relay REL-MR-120AC/21HC/MS part no: 2987901 at the lowest pricing. In-depth Technical Analysis of REL-MR-120AC/21HC/MS, 2987901 feature mechanical service life of 5x 106 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 120 V AC, with an input voltage range of 93.6 V AC ... 174 V AC. The typical input current at UN is 7 mA with a response time of 3 ms ... 12 ms (depending on phase relation). The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 12 V (at 10 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 32 A (20 ms), and a minimum switching current of 10 mA (at 12 V). The interrupting rating for ohmic loads is 4000 VA (for 250 V AC). The connection method is via a Plug / solder connection, with a degree of protection rated at -. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 70 °C. Elevate Your Project with a Quote for your requirement of Phoenix Input Voltage 120V Single Relay. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.