REL-MR- 48DC/21HC: 2834821 - Phoenix 8.7 mA Input Current Single Relay
Technical Specifications of Phoenix 8.7 mA Input Current Single Relay REL-MR- 48DC/21HC 2834821:
Spec | Value |
---|---|
Product Type | Single relay |
Mechanical service life | 3x 107 cycles |
Nominal input voltage UN | 48 V DC |
Input voltage range | 31.2 V DC ... 115.2 V DC |
Phoenix 8.7 mA Input Current Single Relay REL-MR- 48DC/21HC, 2834821 Technical Specifications:
Specification | Value |
---|---|
Product type | Single relay |
Mechanical service life | 3x 107 cycles |
Insulation | - |
Overvoltage category | III |
Pollution degree | 3 |
Service life electrical | see diagram |
Maximum power dissipation for nominal condition | 0.42 W |
Test voltage (Winding/contact) | 5 kV AC (50 Hz, 1 min., winding/contact) |
Test voltage (Changeover contact/changeover contact) | - |
Rated insulation voltage | - |
Rated surge voltage | - |
Nominal input voltage UN | 48 V DC |
Input voltage range | 31.2 V DC ... 115.2 V DC |
Drive and function | monostable |
Drive (polarity) | non-polarized |
Typical input current at UN | 8.7 mA |
Typical response time | 3 ms |
Coil voltage | - |
Status display | - |
Contact switching type | 1 changeover contact |
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC |
Minimum switching voltage | 12 V (at 10 mA) |
Limiting continuous current | 16 A |
Maximum inrush current | 50 A (20 ms) |
Min. switching current | 10 mA (at 12 V) |
Interrupting rating (ohmic load) max. | 384 W (at 24 V DC) |
Connection method | Plug / solder connection |
Width | 12.7 mm |
Height | 29 mm |
Depth | 15.7 mm |
Degree of protection | RT II |
Degree of protection (Installation location) | - |
Ambient temperature (operation) | -40 °C ... 85 °C |
Ambient temperature (storage/transport) | - |
Standards/regulations | IEC 60664 |
Mounting type | - |
Mounting position | any |
Mains frequency | - |
Typical release time range | - |
Coil resistance | 5520 Ω ±10 % (at 20 °C) |
Switching capacity | - |
Motor load according to UL 508 | 1/2 HP, 120 V AC (N/O contact) |
Input power dissipation for UN | - |
3-phase motor load | - |
Product family | - |
Relay type | - |
Test voltage () | - |
Degree of protection (Relay) | - |
Inrush current, minimum | - |
Non-operate voltage | - |
Safe operate voltage | - |
Test voltage (N/O contact / N/O contact) | - |
Ask for the Pricing of Phoenix 8.7 mA Input Current Single Relay REL-MR- 48DC/21HC part no: 2834821 at unbeatable prices. Detailed Specifications of REL-MR- 48DC/21HC, 2834821 feature mechanical service life of 3x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 48 V DC, with an input voltage range of 31.2 V DC ... 115.2 V DC. The typical input current at UN is 8.7 mA with a response time of 7 ms. The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 12 V (at 10 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 50 A (20 ms), and a minimum switching current of 10 mA (at 12 V). The interrupting rating for ohmic loads is 384 W (at 24 V DC). The connection method is via a Plug / solder connection, with a degree of protection rated at RT II. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 85 °C. Now's the Time to Secure a Quote for your requirement of Phoenix 8.7 mA Input Current Single Relay. We're committed to offering more favorable pricing and more responsive support than other Traders.