Phoenix REL-OR3/LDP-48DC/3X21 (2908897) | Grab the Offer
+91 79955 44066 sales@indmall.in

REL-OR3/LDP-48DC/3X21: 2908897 - Phoenix 48VDC Input Voltage Single Relay

Phoenix Contact REL-OR3/LDP-48DC/3X21 2908897

Technical Specifications of Phoenix 48VDC Input Voltage Single Relay REL-OR3/LDP-48DC/3X21 2908897:

SpecValue
Product TypeSingle relay
Mechanical service lifeapprox. 2x 107 cycles
Nominal input voltage UN48 V DC
Input voltage range40.8 V DC ... 52.8 V DC (20 °C)

Phoenix 48VDC Input Voltage Single Relay REL-OR3/LDP-48DC/3X21, 2908897 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service lifeapprox. 2x 107 cycles
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree3
Service life electrical-
Maximum power dissipation for nominal condition1.65 W
Test voltage (Winding/contact)2.5 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)2 kVrms (50 Hz, 1 min., changeover contact/changeover contact)
Rated insulation voltage250 V AC
Rated surge voltage4 kV
Nominal input voltage UN48 V DC
Input voltage range40.8 V DC ... 52.8 V DC (20 °C)
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN31 mA
Typical response time20 ms
Coil voltage-
Status displayLED (yellow)
Contact switching type3 changeover contacts
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage10 V (At 24 mA)
Limiting continuous current10 A
Maximum inrush current30 A (20 ms, N/O contacts)
Min. switching current10 mA (at 24 V)
Interrupting rating (ohmic load) max.240 W (at 24 V DC)
Connection methodPlug-in connection
Width35 mm
Height35 mm
Depth54.4 mm
Degree of protectionRT I
Degree of protection (Installation location)-
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsIEC 60664
Mounting type-
Mounting positionany
Mains frequency-
Typical release time range-
Coil resistance-
Switching capacity2 A (at 24 V, DC13)
Motor load according to UL 508-
Input power dissipation for UN1.5 W
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Ask for the Pricing of Phoenix 48VDC Input Voltage Single Relay REL-OR3/LDP-48DC/3X21 part no: 2908897 at unbeatable prices. Detailed Specifications of REL-OR3/LDP-48DC/3X21, 2908897 feature mechanical service life of approx. 2x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 48 V DC, with an input voltage range of 40.8 V DC ... 52.8 V DC (20 °C). The typical input current at UN is 31 mA with a response time of 18 ms. The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 10 V (At 24 mA). It has a limiting continuous current of 10 A, with a maximum inrush current of 30 A (20 ms, N/O contacts), and a minimum switching current of 10 mA (at 24 V). The interrupting rating for ohmic loads is 240 W (at 24 V DC). The connection method is via a Plug-in connection, with a degree of protection rated at RT I. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 70 °C. Now's the Time to Secure a Quote for your requirement of Phoenix 48VDC Input Voltage Single Relay. We're committed to offering more favorable pricing and more responsive support than other Traders.