REL-PR1-220DC/1/MB: 2908046 - Phoenix Contact Blowout Magnet Single Relays

Phoenix Contact REL-PR1-220DC/1/MB 2908046

Technical Specifications of Phoenix Contact Blowout Magnet Single Relays REL-PR1-220DC/1/MB 2908046:

SpecValue
Product TypeSingle relay
Mechanical service lifeapprox. 2x 107 cycles
Nominal input voltage UN220 V DC
Input voltage range187 V DC ... 242 V DC

Phoenix Contact Blowout Magnet Single Relays REL-PR1-220DC/1/MB, 2908046 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service lifeapprox. 2x 107 cycles
Insulation-
Overvoltage categoryIII
Pollution degree3
Service life electricalsee diagram
Maximum power dissipation for nominal condition1.61 W
Test voltage (Winding/contact)2.5 kV (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)-
Rated insulation voltage-
Rated surge voltage4 kV
Nominal input voltage UN220 V DC
Input voltage range187 V DC ... 242 V DC
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN7.3 mA
Typical response time15 ms
Coil voltage-
Status display-
Contact switching type1 N/O contact
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage440 V AC
Minimum switching voltage5 V (At 24 mA)
Limiting continuous current16 A
Maximum inrush current50 A (20 ms)
Min. switching current5 mA (at 24 V)
Interrupting rating (ohmic load) max.384 W (at 24 V DC)
Connection methodPlug-in connection
Width38.6 mm
Height36.1 mm
Depth45.5 mm
Degree of protectionRT I
Degree of protection (Installation location)-
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsIEC 60664
Mounting type-
Mounting positionany
Mains frequency-
Typical release time range-
Coil resistance-
Switching capacity1 A (220 V, DC13)
Motor load according to UL 508-
Input power dissipation for UN-
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Obtain a Quote for Phoenix Contact Blowout Magnet Single Relays REL-PR1-220DC/1/MB part no: 2908046 at economical prices. Specifications Overview for REL-PR1-220DC/1/MB, 2908046 reveals mechanical service life of approx. 2x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 220 V DC, with an input voltage range of 187 V DC ... 242 V DC. The typical input current at UN is 7.3 mA with a response time of 20 ms. The sensor supports a maximum switching voltage of 440 V AC, and a minimum switching voltage of 5 V (At 24 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 50 A (20 ms), and a minimum switching current of 5 mA (at 24 V). The interrupting rating for ohmic loads is 384 W (at 24 V DC). The connection method is via a Plug-in connection, with a degree of protection rated at RT I. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 70 °C. Take the First Step with a Quote for your requirement of Phoenix Contact Blowout Magnet Single Relays. Our commitment to better pricing and exceptional support sets us apart from other Competitors.