Technical Specifications of Phoenix 48 V DC Coil Voltage Single Relay REL-PR1- 48DC/1/MB 2908613:
Spec | Value |
---|---|
Product Type | Single relay |
Mechanical service life | approx. 2x 107 cycles |
Nominal input voltage UN | 48 V DC |
Input voltage range | - |
Phoenix 48 V DC Coil Voltage Single Relay REL-PR1- 48DC/1/MB, 2908613 Technical Specifications:
Specification | Value |
---|---|
Product type | Single relay |
Mechanical service life | approx. 2x 107 cycles |
Insulation | - |
Overvoltage category | III |
Pollution degree | 3 |
Service life electrical | see diagram |
Maximum power dissipation for nominal condition | 1.9 W |
Test voltage (Winding/contact) | 2.5 kV (50 Hz, 1 min., winding/contact) |
Test voltage (Changeover contact/changeover contact) | - |
Rated insulation voltage | - |
Rated surge voltage | 4 kV |
Nominal input voltage UN | 48 V DC |
Input voltage range | - |
Drive and function | monostable |
Drive (polarity) | non-polarized |
Typical input current at UN | - |
Typical response time | 15 ms |
Coil voltage | - |
Status display | - |
Contact switching type | 1 N/O contact |
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 440 V AC |
Minimum switching voltage | 5 V (At 24 mA) |
Limiting continuous current | 16 A |
Maximum inrush current | 50 A (20 ms) |
Min. switching current | 5 mA (at 24 V) |
Interrupting rating (ohmic load) max. | 384 W (at 24 V DC) |
Connection method | Plug-in connection |
Width | 38.6 mm |
Height | 36.1 mm |
Depth | 45.5 mm |
Degree of protection | RT I |
Degree of protection (Installation location) | - |
Ambient temperature (operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Standards/regulations | IEC 60664 |
Mounting type | - |
Mounting position | any |
Mains frequency | - |
Typical release time range | - |
Coil resistance | - |
Switching capacity | 1 A (at 220 V, DC13) |
Motor load according to UL 508 | - |
Input power dissipation for UN | - |
3-phase motor load | - |
Product family | - |
Relay type | - |
Test voltage () | - |
Degree of protection (Relay) | - |
Inrush current, minimum | - |
Non-operate voltage | - |
Safe operate voltage | - |
Test voltage (N/O contact / N/O contact) | - |
Obtain a Quote for Phoenix 48 V DC Coil Voltage Single Relay REL-PR1- 48DC/1/MB part no: 2908613 at economical prices. Specifications Overview for REL-PR1- 48DC/1/MB, 2908613 reveals mechanical service life of approx. 2x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 48 V DC, with an input voltage range of -. The typical input current at UN is - with a response time of 20 ms. The sensor supports a maximum switching voltage of 440 V AC, and a minimum switching voltage of 5 V (At 24 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 50 A (20 ms), and a minimum switching current of 5 mA (at 24 V). The interrupting rating for ohmic loads is 384 W (at 24 V DC). The connection method is via a Plug-in connection, with a degree of protection rated at RT I. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 70 °C. Take the First Step with a Quote for your requirement of Phoenix 48 V DC Coil Voltage Single Relay. Our commitment to better pricing and exceptional support sets us apart from other Competitors.