Reer Safety EOS2 1354 XM (1320328) | Call For Pricing
+91 79955 44066 sales@indmall.in

EOS2 1354 XM: 1320328 - Reer Safety 46 Beams Light Curtains

Technical Specifications of Reer Safety 46 Beams Light Curtains EOS2 1354 XM 1320328:

SpecValue
Safety levelType 2 - PL c
Protected height (mm)1360
Number of Beams46
ConnectionsM12 5-pole connector (emitter). M12 8-pole connector (receiver)

Reer Safety 46 Beams Light Curtains: EOS2 1354 XM - 1320328

SpecificationValue
Safety levelType 2 - PL c
Protected height (mm)1360
Resolution (mm)40
Controlled height (mm)1350
Max. range (m)12
RestartBuilt-in - User selectable automatic or manual
Functioning systemEmitter / Receiver
Safety level (SIL / PL)Type 2 - SIL 1 - SILCL 1 - PL c - Cat. 2
Operating temperature (°C)- 30 ... 55
Response time (ms)See technical manual
Number of beams46
Max. length of the connection cables (m)100 (50 between Master and Slave)
SignallingLEDs for light curtain's status and diagnostics
Safety output type2 fail-safe PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity
ConnectionsM12 5-pole connector (emitter). M12 8-pole connector (receiver)
MTTFD (ISO13849) years196.8
PFHD (IEC 61508)55
Safety outputs2 OSSD PNP (400 mA at 24 VDC)
Safety functionsIntegrated
DetectionHand
Protective enclosuresNone
Product classC
Custom tariff85365019
Power supply (VDC)24 ± 20%
Overall height (mm)1436.5
Cross section dimensions (mm)28 x 30
Degree of protectionIP65 - IP67
FasteningBack slot with set of LE type brackets (included) or to the top and lower end with swivel brackets SFB E (optional)
Master Slave Modelsyes
Please speak to our Technical Engineer for Reer Safety 46 Beams Light Curtains EOS2 1354 XM part no: 1320328 at attractive prices. Technical Specs Summary of EOS2 1354 XM, 1320328 includes Reer Safety Light Curtains with a safety level of Type 2 - PL c, providing robust protection in industrial environments. The curtains feature a protected height of 1360 and a resolution of 40, with a controlled height of 1350 and a maximum range of 12. Operating within a temperature range of - 30 ... 55, these curtains have a response time of See technical manual and utilize an Emitter / Receiver system. Equipped with 2 fail-safe PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity and M12 5-pole connector (emitter). M12 8-pole connector (receiver), the system ensures reliable performance. The curtains include LEDs for light curtain's status and diagnostics, and the degree of protection is rated at IP65 - IP67 . Match Your Needs with a Quote for your requirement of Reer Safety 46 Beams Light Curtains. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.