Technical Specifications of Reer 432.5 MTTFD Safety Light Curtain EOS4 455 X 1310412:
Spec | Value |
---|---|
Safety Level | Type 4 - PL e |
Protected Height (mm) | 460 |
Number of Beams | 12 |
Connections | M12 5-pole connector (emitter). M12 8-pole connector (receiver) |
Reer 432.5 MTTFD Safety Light Curtain: EOS4 455 X - 1310412
Specification | Value |
---|---|
Safety Level | Type 4 - PL e |
Protected Height (mm) | 460 |
Resolution (mm) | 50 |
Controlled Height (mm) | 450 |
Max. Range (m) | 12 |
Restart | Built-in - User selectable automatic or manual |
Functioning System | Emitter / Receiver |
Safety Level (SIL / PL) | Type 4 - SIL 3 - SILCL 3 - PL e - Cat. 4 |
Operating Temperature (°C) | - 30 ... 55 |
Response Time (ms) | 4.5 |
Number of Beams | 12 |
Max. Length of the Connection Cables (m) | 100 |
Signalling | LEDs for light curtain's status and diagnostics |
Safety Output Type | 2 fail-safe PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity |
Connections | M12 5-pole connector (emitter). M12 8-pole connector (receiver) |
MTTFD (ISO13849) years | 432.2 |
PFHD (IEC 61508) | 9.15E-09 |
Safety Outputs | 2 OSSD PNP (400 mA at 24 VDC) |
Safety Functions | Integrated |
Detection | Body |
Protective Enclosures | None |
Packaging Dimensions HxLxW (mm) | 145 x 540 x 200 |
Product Class | C |
Power Supply (VDC) | 24 ± 20% |
Overall Height (mm) | 513 |
Cross Section Dimensions (mm) | 28 x 30 |
Degree of Protection | IP65 - IP67 |
Fastening Gross | Back slot with set of LE type brackets (included) or to the top and lower end with swivel brackets SFB E (optional) |
Weight (g) | 1826.96 |
Please speak to our Technical Engineer for Reer 432.5 MTTFD Safety Light Curtain EOS4 455 X part no: 1310412 at attractive prices. Technical Specs Summary of EOS4 455 X, 1310412 includes 50 resolution, ensuring precise detection. It operates at a 4.5 response time with a 12 range. The Emitter / Receiver pair meets Type 4 - SIL 3 - SILCL 3 - PL e - Cat. 4 standards, with an operating temperature range of - 30 ... 55. It includes LEDs for light curtain's status and diagnostics and uses M12 5-pole connector (emitter). M12 8-pole connector (receiver). The device is IP65 - IP67 rated for durability, with an overall length of 100. It has 2 fail-safe PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity, and ensuring precise Body, detection. With IP65 - IP67, protection and flexible mounting options, it's designed for versatile use in industrial applications. Match Your Needs with a Quote for your requirement of Reer 432.5 MTTFD Safety Light Curtain. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.