Technical Specifications of Reer 4 Test Output Safety Controllers MOSAIC M1SC 1100004:

SpecValue
Safety LevelPL e
Safety Inputs8 digital inputs
ConnectionsRemovable terminal blocks. clamp contacts
Safety Outputs4 single OSSD. or 2 pairs (400 mA)

Reer Safety 4 Test Output Safety Controllers MOSAIC M1S COM, 1100006 Technical Specifications:

SpecificationValue
Safety levelPL e
Safety inputs8 digital inputs
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (°C)- 10 ... 55
SignallingLEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition
Safety output type4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity
ConnectionsRemovable terminal blocks. clamp contacts
MTTFD (ISO13849) years30 ... 100
PFHD (IEC 61508)1.34E-08
Safety outputs4 single OSSD. or 2 pairs (400 mA)
Status outputs4 PNP (100 mA)
Test outputs4
Storage temperature (°C)-20 ... +85
MSC connector providedNo
Connection with MSC BUSYes
Start/Restart inputs and EDM4
Housing for MCMYes
USB inputYes
Packaging dimensions HxLxW (mm)36 x 127 x 113
Product classC
Custom tariff85371091
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)108 x 22.5 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Gross weight (g)206.8
Obtain a Quote for Reer 4 Test Output Safety Controllers MOSAIC M1SC part no: 1100004 at economical prices. Specifications Overview for MOSAIC M1SC, 1100004 reveals provide top-tier protection with PL e safety level, featuring 8 digital inputs, SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition. Equipped with 4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. clamp contacts, coupled 4 single OSSD. or 2 pairs (400 mA) and 4 test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 206.8 g, they offer reliable performance for industrial applications. Take the First Step with a Quote for your requirement of Reer 4 Test Output Safety Controllers. Our commitment to better pricing and exceptional support sets us apart from other Competitors.