MOSAIC MI8O2: 1100010 - Reer 2 Status PNP Output Safety Controllers

Technical Specifications of Reer Safety Controllers with EtherCAT Interface MOSAIC M1SC COM 1100007:

SpecValue
Safety LevelPL e
Safety Inputs8 digital inputs
ConnectionsRemovable terminal blocks. clamp contacts
Safety Outputs4 single OSSD. or 2 pairs (400 mA)

Reer 2 Status PNP Output Safety Controllers MOSAIC MI8O2, 1100010 Technical Specifications:

SpecificationValue
Safety levelPL e
Safety inputs8 digital inputs
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (°C)- 10 ... 55
SignallingLEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition. Specific LED indicator for the Fieldbus
Safety output type4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity
ConnectionsRemovable terminal blocks. clamp contacts
MTTFD (ISO13849) years
PFHD (IEC 61508)
Safety outputs4 single OSSD. or 2 pairs (400 mA)
Status outputs4 PNP (100 mA)
Test outputs4
Storage temperature (°C)-20 ... +85
MSC connector providedNo
Connection with MSC BUSYes
Start/Restart inputs and EDM4
Housing for MCMYes
USB inputYes
Packaging dimensions HxLxW (mm)58 x 127 x 113
Product classC
Custom tariff85371091
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)108 x 45 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Gross weight (g)
Give Us a Call for Reer Safety Controllers with EtherCAT Interface MOSAIC M1SC COM part no: 1100007 at the lowest pricing. In-depth Technical Analysis of MOSAIC M1SC COM, 1100007 feature provide top-tier protection with PL e safety level, featuring 8 digital inputs, SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition. Specific LED indicator for the Fieldbus. Equipped with 4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. clamp contacts, coupled 4 single OSSD. or 2 pairs (400 mA) and 4 test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 45 x 114.5 and a gross weight of g, they offer reliable performance for industrial applications. Elevate Your Project with a Quote for your requirement of Reer Safety Controllers with EtherCAT Interface. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.