MOSAIC MI8O2: 1100010 - Reer 2 Status PNP Output Safety Controllers
Technical Specifications of Reer Safety Controllers with EtherCAT Interface MOSAIC M1SC COM 1100007:
Spec | Value |
---|---|
Safety Level | PL e |
Safety Inputs | 8 digital inputs |
Connections | Removable terminal blocks. clamp contacts |
Safety Outputs | 4 single OSSD. or 2 pairs (400 mA) |
Reer 2 Status PNP Output Safety Controllers MOSAIC MI8O2, 1100010 Technical Specifications:
Specification | Value |
---|---|
Safety level | PL e |
Safety inputs | 8 digital inputs |
Safety level (SIL / PL) | SIL 3 - SILCL 3 - PL e - Cat. 4 |
Operating temperature (°C) | - 10 ... 55 |
Signalling | LEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition. Specific LED indicator for the Fieldbus |
Safety output type | 4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity |
Connections | Removable terminal blocks. clamp contacts |
MTTFD (ISO13849) years | |
PFHD (IEC 61508) | |
Safety outputs | 4 single OSSD. or 2 pairs (400 mA) |
Status outputs | 4 PNP (100 mA) |
Test outputs | 4 |
Storage temperature (°C) | -20 ... +85 |
MSC connector provided | No |
Connection with MSC BUS | Yes |
Start/Restart inputs and EDM | 4 |
Housing for MCM | Yes |
USB input | Yes |
Packaging dimensions HxLxW (mm) | 58 x 127 x 113 |
Product class | C |
Custom tariff | 85371091 |
Power supply (VDC) | 24 ± 20% |
Dimensions HxWxD (mm) | 108 x 45 x 114.5 |
Degree of protection | IP20 for housing - IP2X for terminal block |
Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
Gross weight (g) |
Give Us a Call for Reer Safety Controllers with EtherCAT Interface MOSAIC M1SC COM part no: 1100007 at the lowest pricing. In-depth Technical Analysis of MOSAIC M1SC COM, 1100007 feature provide top-tier protection with PL e safety level, featuring 8 digital inputs, SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition. Specific LED indicator for the Fieldbus. Equipped with 4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. clamp contacts, coupled 4 single OSSD. or 2 pairs (400 mA) and 4 test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 45 x 114.5 and a gross weight of g, they offer reliable performance for industrial applications. Elevate Your Project with a Quote for your requirement of Reer Safety Controllers with EtherCAT Interface. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.