Reer Safety MOSAIC MI8O2C (1100110) | Contact For Immediate
+91 79955 44066 sales@indmall.in

MOSAIC MI8O4: 1100011 - Reer Safety 8 Digital Input Controllers

Technical Specifications of Reer PL e Safety Level Controllers MOSAIC MI8O2C 1100110:

SpecValue
Safety LevelPL e
Safety Inputs8 digital inputs
ConnectionsRemovable terminal blocks. clamp contacts
Safety Outputs2 OSSD pairs (400 mA)

Reer Safety 8 Digital Input Controllers MOSAIC MI8O4, 1100011 Technical Specifications:

SpecificationValue
Safety levelPL e
Safety inputs8 digital inputs
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (°C)- 10 ... 55
SignallingLEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs and status outputs condition
Safety output type2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity
ConnectionsRemovable terminal blocks. clamp contacts
MTTFD (ISO13849) years30 ... 100
PFHD (IEC 61508)5.68E-09
Safety outputs2 OSSD pairs (400 mA)
Status outputs2 PNP (100 mA)
Test outputs4
Storage temperature (°C)-20 ... +85
MSC connector providedYes
Connection with MSC BUSYes
Start/Restart inputs and EDM2
Housing for MCM
USB input
Packaging dimensions HxLxW (mm)36 x 127 x 113
Product classC
Custom tariff85371091
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)108 x 22.5 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Gross weight (g)185.4
Send Your Inquiry for Reer PL e Safety Level Controllers MOSAIC MI8O2C part no: 1100110 with cost-effective solutions. Essential Technical Specs of MOSAIC MI8O2C, 1100110 are provide top-tier protection with PL e safety level, featuring 8 digital inputs, SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs and status outputs condition. Equipped with 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. clamp contacts, coupled 2 OSSD pairs (400 mA) and 4 test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 185.4 g, they offer reliable performance for industrial applications. Capture the Best Deal with a Quote for your requirement of Reer PL e Safety Level Controllers. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.