MOSAIC MO2: 1100030 - Reer SIL 3 Safety Controllers

Technical Specifications of Reer SIL 3 Safety Controllers MOSAIC MO2 1100030:

SpecValue
Safety LevelPL e
Safety Inputs
ConnectionsRemovable terminal blocks. screw contacts
Safety Outputs2 OSSD pairs (400 mA)

Reer SILCL 3 Safety Controllers MOSAIC MO2C, 1100130 Technical Specifications:

SpecificationValue
Safety levelPL e
Safety inputs
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (°C)- 10 ... 55
SignallingLEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition
Safety output type2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity
ConnectionsRemovable terminal blocks. screw contacts
MTTFD (ISO13849) years30 ... 100
PFHD (IEC 61508)4.09E-09
Safety outputs2 OSSD pairs (400 mA)
Status outputs2 PNP (100 mA)
Test outputs
Storage temperature (°C)-20 ... +85
MSC connector providedYes
Connection with MSC BUSYes
Start/Restart inputs and EDM2
Housing for MCM
USB input
Packaging dimensions HxLxW (mm)36 x 127 x 113
Product classC
Custom tariff85371091
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)108 x 22.5 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Gross weight (g)170.4
Obtain a Quote for Reer SIL 3 Safety Controllers MOSAIC MO2 part no: 1100030 at economical prices. Specifications Overview for MOSAIC MO2, 1100030 reveals provide top-tier protection with PL e safety level, featuring , SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition. Equipped with 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. screw contacts, coupled 2 OSSD pairs (400 mA) and test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 170.4 g, they offer reliable performance for industrial applications. Take the First Step with a Quote for your requirement of Reer SIL 3 Safety Controllers. Our commitment to better pricing and exceptional support sets us apart from other Competitors.