Reer Safety MOSAIC MO4LHCS8 (1100032) | Talk To Us Now
+91 79955 44066 sales@indmall.in

MOSAIC MO4LHCS8: 1100032 - Reer Safety Controllers with LED Indications

Technical Specifications of Reer Safety Controllers with LED Indications MOSAIC MO4LHCS8 1100032:

SpecValue
Safety LevelPL e
Safety Inputs
ConnectionsRemovable terminal blocks. screw contacts
Safety Outputs4 single OSSD. or 2 pairs (2 A)

Reer 4 Single OSSD Output Safety Controllers MOSAIC MO4LHCS8C, 1100132 Technical Specifications:

SpecificationValue
Safety levelPL e
Safety inputs
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (°C)- 10 ... 55
SignallingLEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition
Safety output type4 single OSSD. or 2 pairs (PNP 2.0 A per channel. 8 A total)
ConnectionsRemovable terminal blocks. screw contacts
MTTFD (ISO13849) years30 ... 100
PFHD (IEC 61508)9.28E-09
Safety outputs4 single OSSD. or 2 pairs (2 A)
Status outputs8 PNP (100 mA)
Test outputs
Storage temperature (°C)-20 ... +85
MSC connector providedYes
Connection with MSC BUSYes
Start/Restart inputs and EDM4
Housing for MCM
USB input
Packaging dimensions HxLxW (mm)36 x 127 x 113
Product classC
Custom tariff85371091
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)108 x 22.5 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Gross weight (g)185.4
Send Your Inquiry for Reer Safety Controllers with LED Indications MOSAIC MO4LHCS8 part no: 1100032 with cost-effective solutions. Essential Technical Specs of MOSAIC MO4LHCS8, 1100032 are provide top-tier protection with PL e safety level, featuring , SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition. Equipped with 4 single OSSD. or 2 pairs (PNP 2.0 A per channel. 8 A total), they ensure reliable safety outputs. The Removable terminal blocks. screw contacts, coupled 4 single OSSD. or 2 pairs (2 A) and test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 185.4 g, they offer reliable performance for industrial applications. Capture the Best Deal with a Quote for your requirement of Reer Safety Controllers with LED Indications. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.