MOSAIC MO4LHCS8: 1100032 - Reer Safety Controllers with LED Indications
Technical Specifications of Reer Safety Controllers with LED Indications MOSAIC MO4LHCS8 1100032:
Spec | Value |
---|---|
Safety Level | PL e |
Safety Inputs | |
Connections | Removable terminal blocks. screw contacts |
Safety Outputs | 4 single OSSD. or 2 pairs (2 A) |
Reer 4 Single OSSD Output Safety Controllers MOSAIC MO4LHCS8C, 1100132 Technical Specifications:
Specification | Value |
---|---|
Safety level | PL e |
Safety inputs | |
Safety level (SIL / PL) | SIL 3 - SILCL 3 - PL e - Cat. 4 |
Operating temperature (°C) | - 10 ... 55 |
Signalling | LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition |
Safety output type | 4 single OSSD. or 2 pairs (PNP 2.0 A per channel. 8 A total) |
Connections | Removable terminal blocks. screw contacts |
MTTFD (ISO13849) years | 30 ... 100 |
PFHD (IEC 61508) | 9.28E-09 |
Safety outputs | 4 single OSSD. or 2 pairs (2 A) |
Status outputs | 8 PNP (100 mA) |
Test outputs | |
Storage temperature (°C) | -20 ... +85 |
MSC connector provided | Yes |
Connection with MSC BUS | Yes |
Start/Restart inputs and EDM | 4 |
Housing for MCM | |
USB input | |
Packaging dimensions HxLxW (mm) | 36 x 127 x 113 |
Product class | C |
Custom tariff | 85371091 |
Power supply (VDC) | 24 ± 20% |
Dimensions HxWxD (mm) | 108 x 22.5 x 114.5 |
Degree of protection | IP20 for housing - IP2X for terminal block |
Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
Gross weight (g) | 185.4 |
Send Your Inquiry for Reer Safety Controllers with LED Indications MOSAIC MO4LHCS8 part no: 1100032 with cost-effective solutions. Essential Technical Specs of MOSAIC MO4LHCS8, 1100032 are provide top-tier protection with PL e safety level, featuring , SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition. Equipped with 4 single OSSD. or 2 pairs (PNP 2.0 A per channel. 8 A total), they ensure reliable safety outputs. The Removable terminal blocks. screw contacts, coupled 4 single OSSD. or 2 pairs (2 A) and test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 185.4 g, they offer reliable performance for industrial applications. Capture the Best Deal with a Quote for your requirement of Reer Safety Controllers with LED Indications. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.