Technical Specifications of Reer 2NO Safety Relays SR ONE MC 1330812:
Spec | Value |
---|---|
Safety Level | Type 4 - PL e |
Safety relay outputs | 2 NO (6A at 250 VAC) |
Connections | Removable terminal blocks. clamp contacts |
Dimensions HxWxD (mm) | 99 x 35 x 114 |
Reer 2NO Safety Relays SR ONE MC, 1330812 Technical Specifications:
Specification | Value |
---|---|
Safety level | Type 4 - PL e |
Safety level (SIL / PL) | Type 4 - SILCL 3 - PL e - Cat. 4 |
Operating temperature (°C) | - 30 ... 55 |
Response time (ms) | ≤ 20 |
Signalling | LEDs indication of power on. connected light curtains status. Muting status. Override status and fault diagnosis |
Connections | Removable terminal blocks. clamp contacts |
MTTFD (ISO13849) years | The values depend on the type of use. Refer to the technical manual |
PFHD (IEC 61508) | The values depend on the type of use. Refer to the technical manual |
Safety devices to be connected | OSSD outpt devices. Safety light curtains: EOS4 A. EOS2 A. Admiral AD. Admiral AX BK. Vision V. Safety switches: Magnus RFID. Safety laser scanner: UAM |
Safety relay outputs | 2 NO (6A at 250 VAC) |
Product class | C |
Power supply (VDC) | 24 ± 20% |
Dimensions HxWxD (mm) | 99 x 35 x 114 |
Degree of protection | IP2X |
Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
Packaging dimensions HxLxW (mm) | 57 x 158 x 134 |
Custom tariff | 85365080 |
Gross weight (g) | 258.5 |
Start/Restart | Automatic/Manual monitored selectable |
Muting logic | L (One way) logic with 2 sensors - Crossed beams |
Muting timeout | Selectable: 30 sec. or infinite |
Muting inputs | 2 at 24 VDC - PNP or relay - dark on |
Reach Us by Email for Reer 2NO Safety Relays SR ONE MC part no: 1330812 at Discounted Rates. Key Technical Features of SR ONE MC, 1330812 are These interfaces meet Type 4 - SILCL 3 - PL e - Cat. 4 standards, ensuring top-tier protection. Operating in temperatures from - 30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication of power on. connected light curtains status. Muting status. Override status and fault diagnosis and use Removable terminal blocks. clamp contacts. They are compatible with OSSD outpt devices. Safety light curtains: EOS4 A. EOS2 A. Admiral AD. Admiral AX BK. Vision V. Safety switches: Magnus RFID. Safety laser scanner: UAM The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 35 x 114, they operate at 24 ± 20% and offer IP2X protection. Navigate Your Needs with a Quote for your requirement of Reer 2NO Safety Relays. Our pricing and support are unrivaled, especially when compared to other Competitors.