Reer Safety SR SELECT (1330941) | Chat With Us Now | IndMALL
+91 79955 44066 sales@indmall.in

SR SELECT: 1330941 - Reer Safety Relays to connect Safety Light Curtain

Technical Specifications of Reer Safety Relays to connect Safety Light Curtain SR SELECT 1330941:

SpecValue
Safety LevelPL e
Safety relay outputs2 NO (6A at 250 VAC)
ConnectionsRemovable terminal blocks. screw contacts
Dimensions HxWxD (mm)99 x 22.5 x 114.5

Reer Safety Relays to connect Safety Light Curtain SR SELECT, 1330941 Technical Specifications:

SpecificationValue
Safety levelPL e
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (°C)- 30 ... 55
Response time (ms)≤ 20
SignallingLEDs indication for input. outputs status and diagnostics
ConnectionsRemovable terminal blocks. screw contacts
MTTFD (ISO13849) years94 (B10d 800.000)
Safety devices to be connectedSafety Light Curtains. Solid-State-Output Devices (i.e. RFID safety switches). Emergency Stops. Two-Hand Controls and Type 2 Safety Photocells
Safety relay outputs2 NO (6A at 250 VAC)
Product classC
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)99 x 22.5 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Start/RestartAutomatic/Manual selctable through rotative selector
Programmability4 operative mode selectable through rotative selector
Give Us a Call for Reer Safety Relays to connect Safety Light Curtain SR SELECT part no: 1330941 with budget-friendly prices. Technical Attributes are SR SELECT, 1330941 include These interfaces meet SIL 3 - SILCL 3 - PL e - Cat. 4 standards, ensuring top-tier protection. Operating in temperatures from - 30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication for input. outputs status and diagnostics and use Removable terminal blocks. screw contacts. They are compatible with Safety Light Curtains. Solid-State-Output Devices (i.e. RFID safety switches). Emergency Stops. Two-Hand Controls and Type 2 Safety Photocells The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 22.5 x 114.5, they operate at 24 ± 20% and offer IP20 for housing - IP2X for terminal block protection. Navigate Your Needs with a Quote for your requirement of Reer Safety Relays to connect Safety Light Curtain. We excel in offering more cost-effective and supportive solutions than other Competitors.