SR T: 1330805 - Reer Safety Relays to connect Two Hands Control Safety Devices
Technical Specifications of Reer Safety Relays to connect Two Hands Control Safety Devices SR T 1330805:
Spec | Value |
---|---|
Safety Level | PL e |
Safety relay outputs | 2 NO (6A at 250 VAC) |
Connections | Removable terminal blocks. screw contacts |
Dimensions HxWxD (mm) | 99 x 22.5 x 114.5 |
Reer Safety Relays to connect Two Hands Control Safety Devices SR T, 1330805 Technical Specifications:
Specification | Value |
---|---|
Safety level | PL e |
Safety level (SIL / PL) | PL e - SIL 3 - SILCL 3 - Cat. 4 - Type III C (EN 574) |
Operating temperature (°C) | - 30 ... 55 |
Response time (ms) | ≤ 20 |
Signalling | LEDs indication for status and diagnostic: power supply. channel 1 and channel 2 |
Connections | Removable terminal blocks. screw contacts |
MTTFD (ISO13849) years | The values depend on the type of use. Refer to the technical manual |
PFHD (IEC 61508) | The values depend on the type of use. Refer to the technical manual |
Safety devices to be connected | Two hands control safety devices |
Safety relay outputs | 2 NO (6A at 250 VAC) |
Product class | C |
Power supply (VDC) | 24 ± 20% |
Dimensions HxWxD (mm) | 99 x 22.5 x 114.5 |
Degree of protection | IP2X |
Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
Min. switching current at 24 VDC (mA) | 6 |
Simultaneity (s) | ≤ 0.5 |
Obtain a Quote for Reer Safety Relays to connect Two Hands Control Safety Devices SR T part no: 1330805 at economical prices. Specifications Overview for SR T, 1330805 reveals These interfaces meet PL e - SIL 3 - SILCL 3 - Cat. 4 - Type III C (EN 574) standards, ensuring top-tier protection. Operating in temperatures from - 30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication for status and diagnostic: power supply. channel 1 and channel 2 and use Removable terminal blocks. screw contacts. They are compatible with Two hands control safety devices The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 22.5 x 114.5, they operate at 24 ± 20% and offer IP2X protection. Take the First Step with a Quote for your requirement of Reer Safety Relays to connect Two Hands Control Safety Devices. Our commitment to better pricing and exceptional support sets us apart from other Competitors.