Reer Safety SR XMC (1201715) | Get A Quote Today | IndMALL
+91 79955 44066 sales@indmall.in

SR XMC: 1201715 - Reer Type 2, ≤ 20 ms Response Time Safety Relays

Technical Specifications of Reer Type 2, ≤ 20 ms Response Time Safety Relays SR XMC 1201715:

SpecValue
Safety LevelType 2 - PL c
Safety relay outputs2 NO (6A at 250 VAC)
ConnectionsRemovable terminal blocks. clamp contacts
Dimensions HxWxD (mm)99 x 35 x 114

Reer Type 2, ≤ 20 ms Response Time Safety Relays SR XMC, 1201715 Technical Specifications:

SpecificationValue
Safety levelType 2 - PL c
Safety level (SIL / PL)Type 2 - SILCL 1 - PL c - Cat. 2
Operating temperature (°C)-30 ... 55
Response time (ms)≤ 20
SignallingLEDs indication of power on. connected photocells status. Muting sensors status. Muting status. Override status and fault diagnosis
ConnectionsRemovable terminal blocks. clamp contacts
MTTFD (ISO13849) yearsThe values depend on the type of use. Refer to the technical manual
PFHD (IEC 61508)The values depend on the type of use. Refer to the technical manual
Safety devices to be connectedIlion and Ulisse safety photocell
Safety relay outputs2 NO (6A at 250 VAC)
Product classC
Power supply (VDC)24 ± 20%
Dimensions HxWxD (mm)99 x 35 x 114
Degree of protectionIP2X
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Packaging dimensions HxLxW (mm)57 x 158 x 134
Custom tariff85365080
Gross weight (g)258.3
Start/RestartAutomatic/Manual monitored selectable
Muting logicL (One way) logic with 2 sensors - Crossed beams
Muting timeoutSelectable: 30 sec. or infinite
Muting inputs2 at 24 VDC - PNP or relay - dark on
IndMALL Offers Reer Type 2, ≤ 20 ms Response Time Safety Relays SR XMC part no: 1201715 at economical Choices. Product Tech Specs of SR XMC, 1201715 include These interfaces meet Type 2 - SILCL 1 - PL c - Cat. 2 standards, ensuring top-tier protection. Operating in temperatures from -30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication of power on. connected photocells status. Muting sensors status. Muting status. Override status and fault diagnosis and use Removable terminal blocks. clamp contacts. They are compatible with Ilion and Ulisse safety photocell The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 35 x 114, they operate at 24 ± 20% and offer IP2X protection. Now's the Time to Secure a Quote for your requirement of Reer Type 2, ≤ 20 ms Response Time Safety Relays. Trust in our superior pricing and more dedicated support over other Distributors.