SR XMC: 1201715 - Reer Type 2, ≤ 20 ms Response Time Safety Relays
Technical Specifications of Reer Type 2, ≤ 20 ms Response Time Safety Relays SR XMC 1201715:
Spec | Value |
---|---|
Safety Level | Type 2 - PL c |
Safety relay outputs | 2 NO (6A at 250 VAC) |
Connections | Removable terminal blocks. clamp contacts |
Dimensions HxWxD (mm) | 99 x 35 x 114 |
Reer Type 2, ≤ 20 ms Response Time Safety Relays SR XMC, 1201715 Technical Specifications:
Specification | Value |
---|---|
Safety level | Type 2 - PL c |
Safety level (SIL / PL) | Type 2 - SILCL 1 - PL c - Cat. 2 |
Operating temperature (°C) | -30 ... 55 |
Response time (ms) | ≤ 20 |
Signalling | LEDs indication of power on. connected photocells status. Muting sensors status. Muting status. Override status and fault diagnosis |
Connections | Removable terminal blocks. clamp contacts |
MTTFD (ISO13849) years | The values depend on the type of use. Refer to the technical manual |
PFHD (IEC 61508) | The values depend on the type of use. Refer to the technical manual |
Safety devices to be connected | Ilion and Ulisse safety photocell |
Safety relay outputs | 2 NO (6A at 250 VAC) |
Product class | C |
Power supply (VDC) | 24 ± 20% |
Dimensions HxWxD (mm) | 99 x 35 x 114 |
Degree of protection | IP2X |
Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
Packaging dimensions HxLxW (mm) | 57 x 158 x 134 |
Custom tariff | 85365080 |
Gross weight (g) | 258.3 |
Start/Restart | Automatic/Manual monitored selectable |
Muting logic | L (One way) logic with 2 sensors - Crossed beams |
Muting timeout | Selectable: 30 sec. or infinite |
Muting inputs | 2 at 24 VDC - PNP or relay - dark on |
IndMALL Offers Reer Type 2, ≤ 20 ms Response Time Safety Relays SR XMC part no: 1201715 at economical Choices. Product Tech Specs of SR XMC, 1201715 include These interfaces meet Type 2 - SILCL 1 - PL c - Cat. 2 standards, ensuring top-tier protection. Operating in temperatures from -30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication of power on. connected photocells status. Muting sensors status. Muting status. Override status and fault diagnosis and use Removable terminal blocks. clamp contacts. They are compatible with Ilion and Ulisse safety photocell The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 35 x 114, they operate at 24 ± 20% and offer IP2X protection. Now's the Time to Secure a Quote for your requirement of Reer Type 2, ≤ 20 ms Response Time Safety Relays. Trust in our superior pricing and more dedicated support over other Distributors.